• Clean and disinfect the nebulizer kit, mask, mouthpiece or nosepiece before
using them when as follows:
- the first time after purchase.
- if the device has not been used for a long period of time
- if more than one person uses the same device
• Be sure to wash or wipe the parts after use, and ensure that they are thoroughly
disinfected and dried, and stored in a clean location.
• Do not leave the cleaning solution to dry on the parts.
Caution:
Indicates a potentially hazardous situation which if not avoided, may result in minor
or moderate injury, or physical damage.
(Usage)
• In order to prevent strangulation by the power cord or air tube, or injuries caused by
mishandling, please provide close supervision when this device is used by, on, or
near children or invalids.
• Make sure that the parts are attached correctly.
• Make sure that the vaporizer head is correctly installed before use.
• Make sure that the air filter is correctly attached.
• Make sure that the air filter is clean. If the air filter has been used for more than
60 days, replace it with a new one.
• Do not spill liquid or medication on the compressor.
• Do not tilt the nebulizer kit at an angle of greater than 45 degrees in all directions
or shake it while in use.
• Do not use or store the device while the air tube is creased.
• Use only original nebulizing parts, air tube, air filter and air filter cover.
• Do not add more than 7 ml of medication to the medication tank.
• Do not carry or leave the nebulizer kit while the medication tank contains
medication.
• Do not leave the device unattended with infants or persons who cannot express
their consent.
• Do not subject the device or the parts to any strong shocks such as dropping on
the floor.
• Do not distort the vaporizer head, or jab the nozzle of the medication tank with a
pin or any sharp object.
• Do not insert fingers or objects inside the compressor.
• Do not disassemble or attempt to repair the compressor or AC adapter.
• Do not leave the device or its parts where it will be exposed to extreme
temperatures or changes in humidity, such as in a vehicle during the summer, or
where it will be exposed to direct sunlight.
• Do not block the air filter cover.
• Do not use the device while sleeping or if drowsy.
• To avoid injury to the nose mucosa, do not squeeze the nosepiece into the back
of the nose.
• Do not block the slit between the cap and the inhalation air inlet.
• Approved for human use only.
• If the device is used continuously, the service life of the device may be shortened.
• Limit use to 20 minutes at a time, and allow a 40 minute interval before using the
device again.
• When using the device, the main unit may become hot.
Important safety instructions