Omron NE-C803 Instruction Manual

Omron NE-C803 Instruction Manual

Compressor nebulizer
Hide thumbs Also See for NE-C803:

Advertisement

Compressor Nebulizer
NE-C803 (NE-C803-E)
Instruction Manual
IM-NE-C803-E-02-10/2014
8300641-7B
EN
FR
DE
IT
ES
NL
RU
AR

Advertisement

Table of Contents
loading

Summary of Contents for Omron NE-C803

  • Page 1 Compressor Nebulizer NE-C803 (NE-C803-E) Instruction Manual IM-NE-C803-E-02-10/2014 8300641-7B...
  • Page 2: Table Of Contents

    Technical data ......................18 Guarantee ......................... 21 Introduction Thank you for purchasing the OMRON COMP AIR basic. This product was developed in conjunction with respiratory therapists for the successful treatment of asthma, chronic bronchitis, allergies and other respiratory disorders. This is a medical device. Operate the device only as instructed by your doctor and/or respiratory therapist.
  • Page 3: Intended Use

    Legally certified medical experts, such as doctor, nurse and therapist. Caregiver or patient under the guidance of qualified medical experts for home treatment. The user should also be capable of understanding general operation of NE-C803 and the content of this instruction manual. Intended Patients This product should not be used on patients, who are unconscious or are not breathing spontaneously.
  • Page 4: Important Safety Instructions

    Do not operate the device with a damaged power cord or plug. Keep the power cord away from heated surfaces. Use only original OMRON AC adapter. Use of unsupported AC adapter may damage the device. (Cleaning and disinfecting) Observe the rules below when cleaning or disinfecting parts. Failure to observe these rules may result in damage, inefficient nebulization or infection.
  • Page 5 Do not wind the power cord around the compressor or AC adapter. Do not pull the power cord of AC adapter. Changes or modifications not approved by OMRON HEALTHCARE will void the user warranty. Always remove the AC adapter from the device after use and before cleaning.
  • Page 6 General Safety Precautions: Inspect the device before using them each time, and check that there are no problems. In particular, be sure to check the following: - That the nozzle or air tube are not damaged. - That the nozzle is not blocked. - That the compressor operates normally.
  • Page 7: Know Your Unit

    Know your unit Compressor (Main Unit) x 1 Rear View Power Connector Air Tube Connector Nebulizer Kit Holder Air Filter Cover *Air filter inside Power Switch Nebulizer Kit x 1 Mouthpiece x 1 Nosepiece x 1 Inhalation Top Adult Mask (PVC) x 1 Child Mask (PVC) x 1 Vaporizer Head Medication Tank...
  • Page 8: Optional Medical Accessories

    Optional Medical Accessories (within the scope of EC Medical Device Directive 93/42/EEC) Product description Model Nebulizer Kit & Mouthpiece Set NEB-NSET3-83E Adult Mask (PVC) NEB-MSLP-E Child Mask (PVC) NEB-MSMP-E Adult Mask (SEBS) NEB-MSLS-E Child Mask (SEBS) Set NEB-MSSS-E Mouthpiece NEB-MP-E Nosepiece NEB-NP-E Air Tube (PVC, 100cm)
  • Page 9: Operating Instructions

    Operating instructions How to use Warning: Clean and disinfect the nebulizer kit, mask, mouthpiece or nosepiece before using them when as follows: - the first time after purchase. - if the device has not been used for a long period of time - if more than one person uses the same device For the instructions, refer to “Cleaning and disinfecting”...
  • Page 10 Make sure that the vaporizer head is securely attached to the inhalation top. Note: The sizes of the left- and right-hand Small Large attached parts of the vaporizer head are not the same. If the vaporizer head is not attached in the correct orientation, it will not nebulize correctly.
  • Page 11 Attach the mask, mouthpiece or nosepiece to the nebulizer kit tightly. Note: Make sure that these attachments are fitted in such a way that the handle is positioned away from the patient. Handle Handle Otherwise, medication may be sprayed on patient’s skin or clothes. Attach the air tube.
  • Page 12 Hold the nebulizer kit as indicated on the right. Follow the instructions of your doctor or respiratory therapist. Exhale as normal through mouthpiece, mask or through the nose. Caution: Do not tilt the nebulizer kit at an angle of greater than 45 Right angle degrees in all directions.
  • Page 13: Care And Maintenance

    Care and maintenance Cleaning and disinfecting Caution: Handling the Vaporizer Head Always wash the vaporizer head after each use. Do not use a brush or pin to clean the vaporizer head. When disinfecting the parts by boiling, be sure to boil them in plenty of water. Do not boil vaporizer head together with objects other than applicable nebulizer accessories.
  • Page 14 : applicable : not applicable Parts Disinfecting method (See the next page) Materials Alcohol o o o Disinfecting ethanol Sodium hypochlorite o o o Milton* (0.1%, 15min.) Quaternary ammonium o o o Osvan* (0.1%, 10min.) Chlorhexidine o o o Hibitane* (0.5%, 30min.) Amphoteric Surfactant...
  • Page 15 A. Use a commercially available disinfectant. Follow the instructions provided by the disinfectant manufacturer. Note: Never clean with benzene or thinner. B. Parts may be boiled between 15 to 20 minutes. After boiling, carefully remove the parts, shake off excess water and allow to air dry in a clean environment.
  • Page 16: Removing Condensation From The Air Tube

    Make sure it is attached properly. Notes: Use only OMRON air filters designed for this device. Do not operate without air filter. Do not wash or clean the air filter. If the air filter becomes wet, replace it. Damp air filters can cause blockages.
  • Page 17: Troubleshooting

    Do not cover the compressor during very hot. covered? operation. Note: If the suggested remedy does not solve the problem, do not try to repair the device - the device are not user serviceable. Return the device to an authorized OMRON retail outlet or distributor.
  • Page 18: Technical Data

    = Power on Notes: Subject to technical modification without prior notice. This OMRON product is produced under the strict quality system of OMRON HEALTHCARE Co., Ltd., Japan. The device may not work if the temperature and voltage conditions are different to those defined in the specifications.
  • Page 19 Technical data for the OMRON NE-C803 Compressor with the Nebulizer kit: **MMAD Approx. 3μm Particle Size: MMAD = Mass Median Aerodynamic Diameter 10ml maximum Medication Tank Capacity: Appropriate Medication Quantities: 2ml minimum - 10ml maximum *Less than 45dB Sound: *Approx. 0.30ml/min (by weight loss) Nebulization Rate: ** 0.37ml (2ml, 1%NaF)
  • Page 20 This medical device manufactured by OMRON HEALTHCARE conforms to this EN60601-1- 2:2007 standard for both immunity and emissions. Nevertheless, special precautions need to be observed: Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic fields, near the medical device.
  • Page 21: Guarantee

    This product is guaranteed by OMRON for a period of 3 years after the date of purchase. The proper construction, workmanship and materials of this product is guaranteed by OMRON.
  • Page 22 EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com OMRON HEALTHCARE MANUFACTURING VIETNAM CO., LTD. No.28 VSIP II, Street 2, Vietnam-Singapore Industrial Park II, Production facility Binh Duong Industry-Services-Urban Complex, Hoa Phu Ward, Thu Dau Mot City, Binh Duong Province, Vietnam OMRON HEALTHCARE UK LTD.

This manual is also suitable for:

Ne-c803-eNe-c803-uk

Table of Contents