MAINT=number_of_hours_downh
The following AutoSupport message suppresses automatic case creation for two hours:
system node autosupport invoke -node * -type all -message MAINT=2h
3. Check the version of ONTAP the system is running on the impaired node if up, or on the partner node if the
impaired node is down, using the
◦ If <lno-DARE> is displayed in the command output, the system does not support NVE, proceed to shut
down the controller.
◦ If <lno-DARE> is not displayed in the command output, and the system is running ONTAP 9.5, go to
[Option 1: Checking NVE or NSE on systems running ONTAP 9.5 and
◦ If <lno-DARE> is not displayed in the command output, and the system is running ONTAP 9.6 or later,
go to
[Option 2: Checking NVE or NSE on systems running ONTAP 9.6 and
4. If the impaired node is part of an HA configuration, disable automatic giveback from the healthy node:
storage failover modify -node local -auto-giveback false
modify -node local -auto-giveback-after-panic false
Option 1: Check NVE or NSE on systems running ONTAP 9.5 and earlier
Before shutting down the impaired node, you need to check whether the system has
either NetApp Volume Encryption (NVE) or NetApp Storage Encryption (NSE) enabled. If
so, you need to verify the configuration.
Steps
1. Connect the console cable to the impaired node.
2. Check whether NVE is configured for any volumes in the cluster:
If any volumes are listed in the output, NVE is configured and you need to verify the NVE configuration. If
no volumes are listed, check whether NSE is configured.
3. Check whether NSE is configured:
◦ If the command output list the drive details with Mode & Key ID information, NSE is configured and you
need to verify the NSE configuration.
◦ If NVE and NSE are not configured, it's safe to shut down the impaired node.
Verifying NVE configuration
Steps
1. Display the key IDs of the authentication keys that are stored on the key management servers:
key-manager query
◦ If the
Restored
the impaired node.
◦ If the
Restored
unavailable, you need to complete some additional steps.
◦ If you see the message This command is not supported when onboard key management is enabled,
you need to complete some other additional steps.
2. If the
column displayed anything other than yes, or if any key manager displayed
Restored
2
version -v
storage encryption disk show
column displays
and all key managers display available, it's safe to shut down
yes
column displays anything other than yes, or if any key manager displays
command:
volume show -is-encrypted true
cluster1:*>
earlier].
later].
or
storage failover
security
Need help?
Do you have a question about the FAS8200 and is the answer not in the manual?
Questions and answers