Diagnostics - Nice ROBO600 Instructions And Warnings For Installation

For sliding gates
Table of Contents

Advertisement

"Move anyway" function
If some safety device is not working or is faulty, it is possible to control and move the gate anyway in "Hold-to-run" mode. For further details,
please refer to the tearout insert "USER GUIDE" (final part of the manual).
9

DIAGNOSTICS

Some devices are display messages to identify their status and faults.
9.1 - Control unit signals
The leds on the control unit issue signals to indicate their normal/faulty operation.
Table 13 lists the signals:
OK LED
Cause
Red and green
Serious
leds OFF
Red or green
Serious
led ON
malfunction
1 green flash a
All OK
second
1 red flash
the installation of the devices was
1 sec. pause
not successful or the configuration
1 red flash
of the 1-2 dip switches was changed
without re-learning the devices
2 quick green
There has been a change
flashes
in the input status
2 red flashes
Triggering of a photocell
1 sec. pause
2 red flashes
4 red flashes
Activation of the STOP input
1 sec. pause
4 red flashes
5 red flashes
Internal parameter memorisation
1 sec. pause
error
5 red flashes
7 red flashes
- Error in the internal circuits.
1 sec. pause
- configuration of programming
7 red flashes
switches 1 and 2 changed
8 red flashes
Command already present.
1 sec. pause
8 red flashes
PHOTO led
Cause
Off
Photocell input activated
On
All OK
STOP led
Cause
Off
Activation of the STOP input
On
All OK
SbS led
Cause
Off
Step-by-step command not present
On
Step-by-step command present
FCA led
Cause
Off
FCA limit switch input triggered
On
FCA limit switch input closed
FCC led
Cause
Off
FCC limit switch input triggered
On
FCC limit switch input closed
RADIO led R
Cause
Off
During normal operation, it shows a radio code that is not in the memory has been received.
On
Radio transmitter programming or deletion in progress
Table 13
Solution
Check if the power is on; check fuses have not been tripped: if that is the case, check
the cause of the fault and replace with others of the same value.
Try and switch the control unit off for a few seconds; if the situation does not
change, there is a fault and the electronic board must be replaced.
Normal operation of the control unit.
Check the correct connection of the alt and photocell inputs (see figure 7 and
paragraphs 8.1.1 and 8.1.2) or if the configuration of micro switches 1-2 has been
changed, perform the device learning procedure (paragraph 5.2)
This is normal when there is a change in one of the inputs: SbS,
STOP, triggering of photocells or the radio transmitter is used.
At the beginning of the manoeuvre, one or more photocells are preventing movement:
check to see if there are any obstacles.
During the closing movement it is normal if an obstacle is really present.
At the start of the manoeuvre or during the movement, the STOP input has been
triggered:
check the cause.
Wait at least 30 seconds during which the control unit tries to reset. If the situation
does not change,
it is necessary to delete the memory and carry out the storing procedure again
Disconnect all the power circuits for a few seconds, then try again and send
a command; if the situation does not change there may be a serious fault on the
board or on the motor wiring: check and replace as required.
If the configuration of switches 1 and 2 has been modified, repeat the device learning
procedure or reset the previous configuration
Another command is already present. Remove the command to be able to send
more.
Solution
At the start of the manoeuvre, one or more photocells are preventing movement;
check to see if there are any obstacles, also check the NC connection for faults.
The photocell is aligned and the movement is permitted
Solution
Check the devices connected to the STOP input
STOP Input active
Solution
Solution
Solution
Solution
English – 23

Hide quick links:

Advertisement

Table of Contents
loading