Factory settings (default)
Micro switches:
Semiautomatic (1 = ON - 2 = OFF)
Slow down (8 = ON)
Trimmer TL (Operating Time)
CAUTION! - Every time the selection of micro switches 1 and 2 is changed, it is necessary to repeat the device learning
procedure as described in paragraph 5.2.

7.1 - Adjustable parameters: Trimmer ( TL - TP - F )

The control unit's parameters can be adjusted with three trimmers (fig. 7)
TL (Operating Time)
Operating mode
sets the maximum duration of an
Open or Close movement
TP (Pause Time)
Operating mode
sets the time between the end of
an Open movement and the start
of the next Close movement
F (Force)
CAUTION! – Adjustments to this parameter are safety critical: take great care when making this adjustment.
To adjust the parameter, try various settings: you must measure the force applied by the gate when moving and compare it with local
regulations.

7.2 - Programmable functions

The control unit has a set of micro switches (PROGRAM SWITCH - fig. 7) which activate functions to adapt the automation to the user's needs
as well as making it safer to use.
The micro switches select the operating modes and program the functions, as described in Table 5.
To activate/deactivate a function:
Micro switches (1 ... 10)
IMPORTANT! - Some functions are safety critical; make sure to check which function is safest.
Switches 1-2
Off-Off
On-Off
Off-On
On-On
Switch 3
On
Switch 4
On
16 – English
1
2 3 4 5 6 7 8 9 10
ON
OFF
Trimmer TP (Pause Time)
Adjustment
01.
Select 'Semiautomatic' or 'Automatic' and set micro switch 1 to 'ON'
02.
Run a full Open and Close cycle:
check that the maximum duration setting (Open / Close) is high enough and that a margin of 2 or 3
seconds remains.
Adjust trimmer TL to its maximum setting if necessary.
To adjust the slowdown, see the description of Switch 8 paragraph 7.2.
N.B.: if this time is not sufficient, cut the TLM jumper next to trimmer TL (fig. 7) to obtain a 'Long
Operating Time' (TLM)
Adjustment
01.
select 'Automatic' and set micro switch 2 to 'ON'
02.
set trimmer TP to the desired value;
03.
to check the time setting, run a full Open movements and see how long it takes before the Close
movement starts.
ACTIVATE
ON
Table 5 - Programmable functions
Operation
Manual (hold-to-run)
Semiautomatic
Automatic (automatic closing)
Automatic + Always Closes
Operation
Condominium (not available in manual mode)
Operation
Pre-flashing
Trimmer F (Force)
DEACTIVATE
OFF