NOTICE
! DANGER
NOTICE
9-10
tube in position. If the tube is satisfactory, a thorough
cleaning of the tube and burner chamber should be
performed by blowing out and vacuuming any ash and
carbon buildup. Any build up on the surface of the
burner chamber will cause the heater to lose efficiency.
·
Regular inspection and maintenance is the only way to
ensure safe, reliable and efficient operation of your
heating system.
9.14 Protecting the Heating System
®
Protect the Oasis
Zephyr from temperature extremes and any
dusty, dirty, corrosive environment.
Protect the Oasis
corrosion by using a proper mixture of anti-freeze and water.
Use only a non-toxic propylene glycol-based coolant with
additives generally recognized as safe "GRAS" by the FDA.
Read and follow the anti-freeze manufacturer's instructions for
the type of anti-freeze and mixture recommended for your
application.
Note that any potable water in the Oasis
cold temperatures and will damage the internal parts (including
the heat exchanger). For winterization, it is recommended that
the potable water system be flushed with winterizing antifreeze
that is safe for use in the potable water lines. Alternatively, the
potable water lines can be blown out with air. Note that this
method is not as reliable as using winterizing antifreeze.
Installation Manual for
®
Zephyr from cold temperatures and
Oasis® Zephyr™ HW
Section 9, Operation
®
Zephyr will freeze in
Heating System