Installation
(continued)
Optional Leg Accessory Installation
CAUTION!
Use caution when tipping the dispenser during leg installation. Do
not lay unit on back or side. DO NOT EXCEED 30° angle. Tipping
more than 30° can result in compressor malfunction.
1 . If installing optional 4" Leg Accessory (item# 00956300), place a 5"
(127 mm) spacer underneath the dispenser to ease installation .
2 . Remove four plastic, thread-protecting plugs from bottom of
dispenser .
3 . Screw each leg into chassis (Fig . 3) .
Freestanding Installation
Installation instructions for countertop model may be found on
Installation on page
8.
1 . A clearance of at least 3" (77 mm) is required behind and on
each side of the dispenser for electrical connection and ventilation
(Fig . 4) .
2 . Rough-in the electrical service and water line .
§ Electrical: 115V, single phase, 15A receptacle required . The dispenser
has an integral 8 ft . (2 .4 m) cord and plug .
§ Water: supply line (with shut-off valve) connects to the dispenser's 1/4"
MPT inlet .
NOTICE!
If installing optional Leg Accessory, complete those steps before
proceeding. See
–––––––––––––––––––––––––––––––––––––––––––––––––
page 11
for Leg Accessory instructions.
Dispenser and Icemaker 7CI100A/7FS100A, 15CI100A/15FS100A
Fig . 3
5" (127 mm)
min.
Fig . 4
Countertop
spacer
freestanding models
minimum 3" (77 mm)
clearance required
9