Toshiba BU Series Instruction Manual page 55

Cmos camera
Hide thumbs Also See for BU Series:
Table of Contents

Advertisement

● Setting
- Select the Line of the I/O connector
Set the following value to "LineSelector" register. Select the line to output "LineSource" signal.
Setting value is Enumeration type.
- Select the Input / Output
Set the following value to "LineMode" register. Setting value is Enumeration type.
Line2 is available. Line0 is dedicated input. Line1 is dedicated output.
- Select the source of GPIO output signal
Set the following value to "LineSource" register to change GPIO output signal selected by "LineSelector".
Setting value is Enumeration type.
LineSource
Off (*)
ExposureActive
FrameTransferActive
FrameActive
FrameTriggerWait
AcquisitionActive
Timer0Active
UserOutput
Copyright © 2016 – 2019 Toshiba Teli Corporation, All rights reserved.
LineSelector
Line1 (*)
Line2
* initial factory setting
No output.
Period from exposure start to exposure end.
Period of transferring image data on USB bus.
Period from exposure start to CMOS transfer completion.
Indicating waiting a Random Trigger Shutter.
An External trigger is input during this period, exposure starts immediately.
Indicating the image acquisition status.
This signal can be used as strobe control signal.
The delay time and pulse width of this signal are configurable.
Outputs the value set in "UserOutputValueAll".
I/O connector pin assignment
2 pin: GPIO Output
1 pin: GPIO Input / Output
* initial factory setting
LineMode
Input (*)
Output
Signal description
54 / 80
* initial factory setting
D4256843D
http://www.toshiba-teli.co.jp/en/index.htm
xB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bu132m

Table of Contents