Dc Operation - Honda EU2000i Owner's Manual

Hide thumbs Also See for EU2000i:
Table of Contents

Advertisement

DC OPERATION

The DC receptacle should ONLY be used for charging 12-volt
autom otive type batteries. The DC charging output is not regulated.
When using the DC output, turn the Eco-Throttle sw itch to the OFF
position.
Connecting the battery charging cable (optional equipment):
1.
Before connecting the battery charging cable to a battery that is
installed in a vehicle, disconnect the vehicle battery ground cable
from the negative ( ) battery term inal.
The battery gives off explosive gases; keep sparks, flames and
cigarettes away. Provide adequate ventilation when charging or using
batteries.
WARNING:
Battery posts, term inals and related accessories contain
lead and lead com ponents.
2.
Plug the battery charging cable into the DC receptacle of the
generator.
3.
Connect the red lead of the battery charging cable to the positive
( ) battery term inal and the black lead to the negative ( ) battery
term inal.
4.
Start the generator.
24
Wash hands after handling.
DC CIRCUIT PROTECTOR
DC RECEPTACLE
OFF
ON
PUSH