CONTROLS & FEATURES
Parallel Operation Outlets
These outlets are used for connecting two EU3000is generators for parallel
operation (see page 41). A Honda approved parallel operation cable kit
(optional equipment) is required for parallel operation. This kit can be
purchased from an authorized Honda generator dealer.
AC Circuit Protectors
The AC circuit protectors will automatically switch to OFF if there is a short
circuit or a significant overload of the generator at the 120 V 20 A receptacle or
120 V 23.3 A locking plug receptacle. If an AC circuit protector switches OFF
automatically, check that the appliance is working properly and does not
exceed the rated load capacity of the circuit before resetting the AC circuit
protector ON.
(1) 120 V 20 A
24
PARALLEL OPERATION OUTLETS
AC CIRCUIT PROTECTOR for
Receptacle (1)
AC CIRCUIT PROTECTOR for
Receptacle (2)
(2) 120 V 23.3 A
AC CIRCUIT PROTECTOR
ON
OFF
PUSH