Installation
Metal Feed Tube
NOTE: A tilted face seal nozzle plate (top) (AD) is
required when using a metal feed tube.
1. Install the face seal o-ring into the recess on the
tilted face seal nozzle plate (top) (AD).
AD
Feed Tube
F
. 20
IG
16
2. Attach the metal feed tube to the tilted face seal
F
IG
3. Install the syringe into the syringe bracket, and
4. Replace the receiver head (J).
Face Seal O-Ring
nozzle plate (top) (AD) using the included fasteners.
Torque the fasteners to 0.9 N•m (8.0 lbf-in.).
. 21
fasten the syringe to the metal feed tube.
3A8600B