NOTES:
• Mounting brackets, screws, gaskets and other seal materials are not included.
• Do not install any ducts onto the cold-air supply and cellar-air return.
• Ducts can be used on the hot-air exhaust and ambient-air intake side
• Mounting brackets, screws, gaskets and other seal materials are not included.
1. General Instructions
• The cooling unit produces cooling supplied into the cellar, meanwhile it also
generates heat that must be exhausted outside the cellar. So the cold- air
supply with cellar-air return side and the hot-air exhaust with ambient-air
intake side must be separated and sealed. Through-wall installations can
separate these two sides.
• Furthermore, the condenser of cooling unit must intake adequate fresh
ambient-air to work properly. The ambient-air intake and hot-air exhaust must
not be short-circulated. Both of them must remain unobstructed 36" clearance
all around. The area into which the hot air is exhausted must be well
ventilated. If it is not, heat generated by the unit will build up and the unit will
not operate properly.
• Additionally, cold-air supply from the front grille must remain unobstructed 36"
clearance.
• The ambient temperatures shall not be above and below what are specified.