Installation

Notes:
1. Shut off the cold water supply under the sink or the location where the system will be
installed. If the existing valve is inoperable, the water supply to the house must be shut
off. Then, relieve the water pressure by opening the cold water tap. Do not connect the
system to hot water source.
2. Depending on your plumbing system and sink/countertop type you may need to use tools
like variable speed drill, drill bits, screw driver, wrench, etc. You may want to ask a profes-
sional service provider such as certified plumber to install the inlet valve adapter, faucet,
and drain saddle to assure a trouble-free setup.
3. During installation you will need to cut the supplied ¼" tubing into segments as needed.
Use your utility knife for that or similar tool. See the following charts to determine the
connection scheme and length of hoses necessary. You may need to purchase extra tubing
for far-reaching or other corner case installations.
4. With initial operation, check for leaks. If a leak is observed, verify that the tubing is
pushed into the quick fitting far enough to seal the tubing against the O-ring and that the
tubing was cut at 90°.
7

Advertisement

loading

This manual is also suitable for:

Expert mo530Expert mo520Expert mo510