Safety
2.7

Safety measures at the installation location

Workspace conditions
Containers and hoses
Vent/drain system
2.8

Safety information on explosion protection

Petrochemical products
36 / 158
Ensure that the working area is adequately ventilated.
Observe the emission limits. Install an exhaust-air cleaning system if
necessary.
Do not direct suctioned-off air back into the work room.
Install washing facilities and eye baths in the workplace.
Install a solvent-proof floor.
Creeping vapors can constitute an ignition source. Seal the
room properly to ensure that gases or vapors which could contain igni-
tion sources cannot enter the room.
Install equipment for detecting and reporting gas hazards.
Install emergency-off equipment in easily accessible locations.
Label containers and hoses clearly.
Only conduct work on containers and hoses when they have been thor-
oughly rinsed and rendered inert.
Protect the analyzer from impermissible external warming.
Regularly inspect for leaks.
The vent/drain system may not be used to introduce foreign gases, vapors or
liquids.
Danger of explosions due to impermissible
petrochemical products!
The explosion protection of the individual analyzer has been
exclusively designed for the safety technology characteris-
tics of the petrochemical products specified in the order
documentation.
FOR THIS REASON:
Before switching on and during analyzer operation,
make sure that the supply lines and all
other petrochemical product-conveying parts of the
analyzer only contain the permitted product (for exam-
ple by thorough rinsing and bleeding).
Make sure that the product properties
correspond with the given specifications.
WARNING