Summary of Contents for Bandini Industrie G:B:D: BA24
Page 1
BA24 BA24 - ( AS05100 Apparecchiatura elettronica ISTRUZIONI PER L’INSTALLAZIONE Electronic control unit INSTRUCTIONS FOR INSTALLATIONS...
Page 2
BA24 • Questo prodotto è stato collaudato in GI.BI.DI. verificando la perfetta corrispondenza delle caratteristiche alle direttive vigenti. • La GI.BI.DI. S.r.l. si riserva la facoltà di modificare i dati tecnici senza avviso, in funzione dell'evoluzione del prodotto. LEGGERE ATTENTAMENTE QUESTO MANUALE PRIMA DI PROCEDERE ALL’INSTALLAZIONE. •...
Page 4
BA24 BA24 / AS05100 Control unit Electronic control unit for the automation of one or two motors - 24V dc - for swinging and sliding gates, Type overhead garage doors and barriers Power supply 230Vac monophase 50/60 Hz N° motors 1 or 2 Motor power supply 24 Vdc...
BA24 • COSTA choice with N.C. contact or 8K2 resistive. • Anti-crushing enabling (motion inversion for 2 seconds and stop) or amperometric detection for limit switch. • Specific menu for the exclusion of the accessories not used (picture 1, picture 2 and safety devices). •...
BA24 WARNINGS FOR THE USER In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service. Periodically check functioning of the safety devices. Any repairs must be carried out by specialised personnel using original and certified materials.
Page 7
BA24 STOP input (N.C.). STOP If not used, jumper with terminal n° 29. Opening limit switch input - motor 1 (N.C.). FCAM1 If not used, disable during programming. Closing limit switch input - motor 1 (N.C.). FCCM1 If not used, disable during programming. Opening limit switch input - motor 2 (N.C.).
BA24 PROTECTION FUSES Position Value Type Description 10 A Accessories and motor protection, power supply from battery charger circuit. 10 A Equipment, motor and safety devices protection. 500 mA FAST Accessories protection. PROGRAMMING PROCEDURE AND SYSTEM CONFIGURATION The system adjustments can be accessed via the display. There are 5 different menus marked with the letters A, C, F, H and E.
Page 9
BA24 The third figure is flashing. 4 6 0 0 With the + or – keys, the user selects the third digit of the installer code. When the required digit is selected, press the OK key to confirm and go to step 6. The last figure is flashing.
Page 10
BA24 Use the + and – keys to see the other submenus of the A menu; follow the procedure as before. Press the ESC key to return to the higher level (menu A, C, F, H E). MENÙ C When the 5 main menus are shown on the display (letters A C F H E) and the C is blinking;...
Page 11
BA24 The stored value appears with the first digit blinking. 0 1 0 0 Use the + or - buttons to modify the value of this digit. Use the OK key to confirm and go to step 16. The second digit blinks. 0 1 0 0 Use the + or - buttons to modify the value of this digit.
Page 12
BA24 MENÙ E Enter the submenu E to see the ENABLING/DISABLING setting. A C F H E Press the OK key to enter the menu. E1 = PHOTOCELL 1 Press the OK button in sequence to: enable the input (the Y will appear next to E1) disable the input (the N will appear next to E1) Use the + and –...
Page 13
BA24 The symbols shown at the beginning reappear. In this case, the +, - and OK buttons have the following meanings: » START » PEDESTRIAN » STOP MENU A: SYSTEM CONFIGURATION AND OPERATING LOGIC SELECTION KEY + : enters the following menu A1-A2-A3… KEY - : enters the previous menu A3-A2-A1…...
Page 14
BA24 It enables the STEP BY STEP WITH STOP logic Operation: open Start stop Next Start close Next Start Next Start open If automatic closing has been activated (menu C1) and the opening STEP BY STEP phase is at the end of the cycle, when the pause time has elapsed WITH STOP LOGIC (menu H9), the control unit automatically closes the gate.
Page 15
BA24 It activates the DEAD MAN logic Operation: Start opens only if the Start key is held down. closes only if the Pedestrian key is held down. Pedestrian In Dead Man's mode the keys on the control unit assume the following meanings: + key open...
Page 16
BA24 Enables 3-second pre-flashing before motor start PRE-FLASHING Disables pre-flashing. The flashlight and the motors start at the same time. Enables the safety devices test. See also menu C20. When the device is activated (edge intercepted), the writing SAF appears on the LCD Operation: PHASE 1: when the Start or the Pedestrian command is given, the amperometric circuit is tested.
Page 17
BA24 Enables the final opening and closing stroke. Operation: At the end of the working time during opening and closing without deceleration, a 2 s pulse is given with the power set in menus F1 and F5. When deceleration is active, the pulse is given at the end of the FINAL OPENING AND deceleration time.
BA24 Enables the RESERVE input for the connection of an external clock. Operation: When the clock closes the contact on the RESERVE input, following a START command the door will open but not close automatically. When the contact on the RESERVE input is opened, the door will EXTERNAL CLOCK automatically close after the pause time.
Page 19
BA24 Enables times programming. AUTOMATIC PROGRAMMING Operation: See “Times self-learning Procedure” MENU F: FORCE AND SPEED ADJUSTEMENT Menu Function Description Adjusts the thrust of motor 1. MOTOR 1 FORCE 0001 = minimum force 0010 = maximum force Adjusts the thrust of motor 1 during deceleration phase. MOTOR 1 DECELERATION 0001 = minimum force SPEED...
BA24 Delay the start in opening of leaf 2 with respect to leaf 1. LEAF 2 PHASE SHIFT TIME In the case of double sliding gate, the time H7 will not be considered. IN OPENING Tmax 100 sec. Delay the start in opening of leaf 1 with respect to leaf 2. In the case of double LEAF 1 PHASE SHIFT TIME sliding gate, the time H8 will not be considered.
Page 21
BA24 Menu Function Status Description Photocell 1 enabled PHOTOCELL 1 Photocell 1 disabled Photocell 2 enabled PHOTOCELL 2 Photocell 2 disabled Edge enabled EDGE (SEFETY DEVICE) Edge disabled TIMES MANAGEMENT T3 ADDITIONAL TIME Additional time at the end of the working time (with full force or during deceleration phase according to the settings) that allows to continue the movement to close the leaf even if there is wind.
Page 22
BA24 • When the leaf 2 arrives at the closing position START the leaf 2 stops. • When the leaf 1 arrives at the closing position START the leaf 1 stops. • At this point the procedure has finished, the blinking menu C21 (without Y) reappears. •...
Page 23
BA24 • with voltage around 20-21Vdc, the battery is exhausted; it is possible to open the door but not to close. When the leaf should start the motion, it does not move and the fault “exhausted battery” is signalled by 4 slow blinks of the flashing light;...
BA24 DEFAULT SETTINGS • Active parameters type A: SWING GATE/OVERHEAD DOOR/BARRIER TYPE 2 MOTORS AUTOMATIC-CONDOMINIUM USING • Active parameters type C: AUTOMATIC CLOSING ENABLED (GENERAL AND PEDESTRIAN) FAST CLOSING DISABLED PRE-FLASHING ENABLED SAFETY DEVICES TEST DISABLED LIMIT SWITCH ENABLED (SINGLE PAIR) DECELERATIONS DISABLED WATER HAMMER DISABLED FINALE CLOSING STROKE DISABLED...
Page 25
BA24 MOTOR 2 CLOSING TIME MOTOR 2 DECELERATION TIME LEAF 2 PHASE SHIFT TIME IN OPENING LEAF 1 PHASE SHIFT TIME IN CLOSING PAUSE TIME PEDESTRIAN OPENING TIME PEDESTRIAN PAUSE TIME NUMBER OF CYCLES 0000 0000 INSTALLER CODE xxxx SOFTWARE VERSION (format: R__xx) 0000 NUMBER OF CYCLES DONE •...
BA24 SIMPLIFIED PROGRAMMING Connect all the connections (wire motors using a 1.5 mm² wire) Enter the installation code, and then set the type of function desired from menu A2/A3. Set the number of motors used. Menu A4/A5. Set the operation mode. Menu A6/A7/A8/A9. Go to menu C21, and select «Y»...
Page 27
BA24 CE Declaration of conformity The manufacturer: GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B, 46025 Poggio Rusco (MN) ITALY Declares that the products: ELECTRONIC CONTROL UNIT BA24 are in conformity with the following CEE Directives: • LVD Directive 2006/95/CE and subsequent amendments; •...
Page 28
GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B 46025 Poggio Rusco (MN) - ITALY Tel. +39.0386.52.20.11 Fax +39.0386.52.20.31 E-mail: comm@gibidi.com Numero Verde: 800.290156 w w w . g i b i d i . c o m...