Connection dia-
The ripple control signal receiver and the I/Os terminal of the inverter can be connected
gram - 2 relays
to one another in accordance with the connection diagram.
If the distance between the inverter and the ripple control signal receiver exceeds 10 m,
at least a CAT 5 cable is recommended and the shield must be connected at one end to
the push-in terminal of the data communication area (SHIELD).
(1)
(2)
Use the preconfigured file for 2-relay mode:
1
2
3
The settings for 2-relay mode are stored.
Ripple control signal receiver with 2 relays, for effective power limitation.
I/Os of the data communication area.
Download the file (.fpc)
under 2-relay mode
Upload the file (.fpc) in the "I/O Power Management" menu using the "Import" button.
Click on the "Save" button.
onto the end device.