Status codes and remedy

Status Codes

1030 - WSD Open (operation LED: lights up red)
Cause:
Display:
Remedy:
OR:
OR:
Danger due to work that has been carried out incorrectly.
This can result in serious injury and damage to property.
A device connected in the WSD chain has interrupted the signal line (e.g. a
surge protective device) or the bypass ex works has been removed and no
trigger device has been installed.
On the inverter website in the "System" → "Event Log" menu or in the user
menu under "Notifications" or in Fronius Solar.web.
If the SPD surge protective device is triggered, the inverter must be repaired
by an authorised specialist.
Install the bypass ex works or a trigger device.
Set the WSD (wired shutdown) switch to position 1 (WSD primary device).
WARNING!
Installing and connecting a surge protective device (SPD) must only be carried out
by service personnel trained by Fronius and only within the scope of the respective
technical regulations.
Follow the safety rules.