Network Addressing; Fluidmesh Radio Transceivers; Connecting And Configuring An Ethernet Edge Device - Cisco FM3500 Endo Installation And Configuration Manual

Ultra-reliable wireless backhaul
Hide thumbs Also See for FM3500 Endo:
Table of Contents

Advertisement

Network addressing

Fluidmesh radio transceivers

Fluidmesh data link layer (layer 2) addressing allows you to configure
each Cisco FM3500 Endo transceiver unit, and each IP device connected
to the unit, according to the IP address class used in the private LAN to
which the Mesh End unit is connected.
Each Fluidmesh radio transceiver unit has a factory-set IP address of
192.168.0.10, and a Netmask of 255.255.255.0.
When a Fluidmesh wireless network is connected to a wired LAN, the
LAN is usually the private control room LAN. Therefore, Fluidmesh radio
transceivers, and all other edge devices that connect the wireless network
to the wired LAN, must be assigned individual LAN IP addresses that are
part of the same subnet. The edge devices will be accessed using those
IP addresses.
A typical network configuration (Fluidmesh Network Addressing) is shown
"Operating the unit in Mesh Point mode or Mesh End mode" (page
in
In this configuration, the private LAN IP address class is 192.168.150.0,
with netmask 255.255.255.0. Note that each device has an IP address
belonging to this subnet.
Multiple Fluidmesh radio transceiver units can be connected through a
network switch, forming radio clusters. The proprietary routing protocol will
run automatically on the wired part of the network. To activate the cluster
feature, transceiver units that are capable of being set in Mesh Point mode
must be set in that mode.

Connecting and configuring an Ethernet edge device

Ethernet edge devices such as IP cameras and Wi-Fi access points can
be connected to the Ethernet ports of the Cisco FM3500 Endo. Such edge
devices must be configured using the IP subnet scheme defined for the
broadcast domain.
The default IP subnet mask for all Fluidmesh devices is 192.168.0.0 /
255.255.255.0.
© 2021 Cisco and/or its affiliates. All rights reserved.
NOTE
Each individual Fluidmesh radio transceiver unit has a factory-
set 5.a.b.c Mesh identification number. Each unit is shipped
from the factory with the same IP address, but with a unique
Mesh identification number.
IMPORTANT
IP addresses must not be duplicated within a network. If
addresses are duplicated, IP address conflicts will occur.
Getting Started
20).
Page 21 of 177

Advertisement

Table of Contents
loading

Table of Contents