Replacement Of Electrical Components; Check Oil Line Seals - Bentone B 55-3R Installation And Maintenance Instruction

Table of Contents

Advertisement

6.5 Check oil line seals

Once the burner has been installed and commissioned, the seals of the
various coupling elements should be checked.
When a leak is detected, it is usually sufficient to tighten the coupling
element that is leaking.
!
Use Loctite 5188 on threaded oil lines.
6.6 Replacement of electrical
components
1.
Switch off the mains power.
!
If the burner is directly connected, ensure that all
components on the burner are without power.
2.
Note the connection of the existing component.
3.
Remove the existing component.
4.
Install the new component using the same wiring as the existing
component or the specified alternative arrangement.
5.
Turn on the mains power.
6.
Check the function of the new component.
7.
Start the burner and check the combustion.
!
When servicing/replacing components that affect combustion, an analysis and
soot test must be carried out on the installation.