CAIRE CHART FreeStyle User Manual page 30

Table of Contents

Advertisement

Recommended separation distances between portable and mobile RF
communications equipment and the FreeStyle or FreeStyle 5
The FreeStyle and FreeStyle 5 are intended for use in an electromagnetic environment in which radiated
RF disturbances are controlled. The customer or the user of the FreeStyle and FreeStyle 5 can help prevent
electromagnetic interference by maintaining a minimum distance between portable and mobile RF
communications equipment (transmitters) and the FreeStyle and FreeStyle 5 as recommended below, according
to the maximum output power of the communications equipment.
Rated maximum
output power of
transmitter
150 kHz to 80 MHz
W
0,01
0,1
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in
metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the
maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and reflection from structures, objects and people.
Classi cation
Type of protection against electric shock:
Class II
Protection from electric shock is
achieved by double insulation.
Degree of protection against electric shock:
degree of protection against electric
shock regarding
1) allowable leakage current;
2) reliability of protective earth connection
(if present).
Not intended for direct cardiac application.
Independent testing for Medical Electrical
Tested to be in compliance with
safety.
Protection against potential electromagnetic or
devices.
(EMC).
30 — MN218 B
Separation distance according to frequency of transmitter
80 MHz to 800 MHz
d
1
2 .
P
d
0.12
0.12
0.38
0.38
1.2
3.8
12
• Tested to be in compliance with RTCA/DO160
Section 21 Category M.
• CISPR 11 / EN 55011 Class B Group 1,
• FCC Part 15, Subpart B – Class B
Unintentional Radiators
Method of cleaning and infection control allowed:
Please refer to "Cleaning, Care, and Proper
Maintenance" section of this FreeStyle User
Manual.
Degree of safety of application in the presence of
Mode of operation:
Continuous duty.
m
800 MHz to 2,5 GHz
1
2 .
P
d
1
0.23
0.73
1.2
2.3
3.8
7.3
12
23
2 .
P