Installation; Wiring; General Wiring Guidelines; Pin Assignment - Pilz PSEN ix2 F8 code Operating Manual

Table of Contents

Advertisement

PSEN ix2 F8 code

Installation

}
The unit should be installed in a lockable control cabinet with a protection type of at
least IP54.
}
Use the notch on the rear of the unit to attach it to a DIN rail.
}
When installed on a vertical mounting rail (35 mm): Secure the unit by using a fixing
element (e.g. retaining bracket or end angle).
}
Circumvention of the safety switch in a reasonably foreseeable manner must be pre-
vented.

Wiring

General wiring guidelines

Please note:
}
Information given in the
}
The device must always be supplied by a single power supply. The power supply must
meet the regulations for extra low voltages with protective separation.
}
Where safety-related applications are concerned, it is essential that short circuits and
open circuits are unable to cause a hazardous condition within a plant. The way in
which this is done will depend on the degree of hazard from the plant section, the
switching frequency of the sensors and the level of safety of the sensors and actuators.

Pin assignment

Terminal block X1
Terminal
11
12
13
14
15
16
17
18
Operating Manual PSEN ix2 F8 code
1003867-EN-02
Technical details [
Device
Function
PSEN 1
Input channel 1 of sensor
Input channel 2 of sensor
24 VDC
0 VDC
Signal output/diagnostic output Y32 of
sensor
Signal input/diagnostic input Y1 of sensor
Output channel 1 of sensor
Output channel 2 of sensor
19]
must be followed.
Cable colour
Pink
White
Brown
Blue
Grey
Red
Green
Yellow