  • Page 1 PSEN ix2 F8 code PSEN sensor technology Operating Manual 1003867-EN-02...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Use of qualified personnel Warranty and liability Disposal Function description Installation Wiring General wiring guidelines Pin assignment Connection to evaluation devices General Independent circuit Series connection of the interface Dimensions Technical details Order reference System Accessories Operating Manual PSEN ix2 F8 code 1003867-EN-02...
  • Page 4: Introduction

    PSEN ix2 F8 code Introduction Validity of documentation This documentation is valid for the product PSEN ix2 F8 code. It is valid until new docu- mentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5: Overview

    Decentralised passive junction for connecting sensors to a Pilz control system. Max. 8 sensors per PSEN ix2 F8 code can be connected Max. 3 PSEN ix2 F8 code with max. 16 subscribers can be connected in series Forwarding of diagnostic information from the connected sensors.
  • Page 6: Front View

    Y1-Y8: Terminals for communication, data inputs from the sensors PSEN [1] Terminal block X6, terminal Y8: Diagnostic input IN for sensor 1 [2] Terminal block X5, terminal Y1: Diagnostic output OUT from sensor 8 Operating Manual PSEN ix2 F8 code 1003867-EN-02...
  • Page 7: Safety

    "System Description Safety Device Diagnostics". Series connection of PSEN sensors and connection to an evaluation device A max. of 8 PSEN sensors can be connected to a PSEN ix2 F8 code. All sensors must be 8-pin, with 2 safety inputs each.
  • Page 8: Use Of Qualified Personnel

    (e.g. Electrical and Electronic Equipment Act). Function description With the help of the PSEN ix2 F8 code, Pilz sensors can be connected in series and con- nected to a fieldbus module for evaluation of diagnostics data. PSEN ix2 F8 code can also be connected in series.
  • Page 9 OUT 2 PSEN 6 OUT 1 OUT 2 PSEN 5 OUT 1 OUT 2 PSEN 4 OUT 1 OUT 2 PSEN 3 OUT 1 OUT 2 PSEN 2 OUT 1 OUT 2 PSEN 1 Operating Manual PSEN ix2 F8 code 1003867-EN-02...
  • Page 10: Installation

    Input channel 2 of sensor White 24 VDC Brown 0 VDC Blue Signal output/diagnostic output Y32 of Grey sensor Signal input/diagnostic input Y1 of sensor Output channel 1 of sensor Green Output channel 2 of sensor Yellow Operating Manual PSEN ix2 F8 code 1003867-EN-02...
  • Page 11 Input channel 2 of sensor White 24 VDC Brown 0 VDC Blue Signal output/diagnostic output Y32 of Grey sensor Signal input/diagnostic input Y1 of sensor Output channel 1 of sensor Green Output channel 2 of sensor Yellow Operating Manual PSEN ix2 F8 code 1003867-EN-02...
  • Page 12 Input channel 2 of sensor White 24 VDC Brown 0 VDC Blue Signal output/diagnostic output Y32 of Grey sensor Signal input/diagnostic input Y1 of sensor Output channel 1 of sensor Green Output channel 2 of sensor Yellow Operating Manual PSEN ix2 F8 code 1003867-EN-02...
  • Page 13 Input channel 1 for last sensor PSEN n Pink Input channel 2 for last sensor PSEN n White Evaluation Output channel 1 for evaluation device Green device Output channel 2 for evaluation device Yellow Operating Manual PSEN ix2 F8 code 1003867-EN-02...
  • Page 14: Connection To Evaluation Devices

    Independent circuit Please note: When connected to the PSEN ix2 F8 code, the sequence of the sensors must be main- tained. – PSEN 1: Terminal block X1, terminals 11-18 –...
  • Page 15 Fig.: Terminal block X1 with three bridges for an unconnected sensor Connection without fieldbus module If the PSEN ix2 F8 code will not be connected to a fieldbus module, the bridges that are inserted on terminals X5 Y2 ‑ Y7 and X6 Y2 ‑ Y7 when the PSEN ix2 F8 code is de- livered must all be removed.
  • Page 16 Y32 Sensor 3 Y1 Sensor 4 Y32 Sensor 4 PSEN ix2 F8 code Sensor 1 Evaluation device O2/A1 Sensor 2 O1/A1 Sensor 3 Sensor 4 Fieldbus module Sensor 5 Sensor 6 Sensor 7 Sensor 8 Operating Manual PSEN ix2 F8 code 1003867-EN-02...
  • Page 17: Series Connection Of The Interface

    Max. 16 sensors can be connected to a fieldbus module. Only seven sensors can be connected to the first PSEN ix2 F8 code. 2 sensors can be connected to the final PSEN ix2 F8 code. The displayed series connection shows a ver- sion with 3 PSEN ix2 F8 code, where the terminal blocks X2, X3 and X4 must be bridged.
  • Page 18 Sensor 15 Sensor 16 PSEN ix2 F8 code Please note: The terminal blocks X2, X3 and X4 at the 3. PSEN ix2 F8 code are not necessary and therefore have to be bridged. Operating Manual PSEN ix2 F8 code 1003867-EN-02...
  • Page 19: Dimensions

    Voltage UB 30 V Kind Environmental data Ambient temperature Temperature range -10 - 55 °C Storage temperature Temperature range -25 - 70 °C Protection type Mounting area (e.g. control cabinet) IP54 Terminals IP20 Operating Manual PSEN ix2 F8 code 1003867-EN-02...
  • Page 20: Order Reference

    540 320 10 m 540 321 20 m 540 333 30 m 540 326 PSEN cable M12‑8af Angled, M12, 8-pin, socket Open cable 540 322 540 323 10 m 540 324 30 m 540 325 Operating Manual PSEN ix2 F8 code 1003867-EN-02...
  • Page 21 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...

This manual is also suitable for: