  • Page 1 PSEN ix2 F4 code PSEN sensor technology Operating Manual 1003823-EN-02...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Use of qualified personnel Warranty and liability Disposal Function description Installation Wiring General wiring guidelines Pin assignment Connection to evaluation devices General Independent circuit Series connection of the interface Dimensions Technical details Order reference System Accessories Operating Manual PSEN ix2 F4 code 1003823-EN-02...
  • Page 4: Introduction

    PSEN ix2 F4 code Introduction Validity of documentation This documentation is valid for the product PSEN ix2 F4 code. It is valid until new docu- mentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5: Overview

    Decentralised passive junction for connecting sensors to a Pilz control system. Max. 4 sensors per PSEN ix2 F4 code can be connected Max. 5 PSEN ix2 F4 code with max. 16 subscribers can be connected in series Forwarding of diagnostic information from the connected sensors.
  • Page 6: Front View

    Y1-Y8: Terminals for communication, data inputs and outputs from the sensors PSEN 1-4 [1] Terminal Y8: Diagnostic input IN for sensor 1 [2] Terminal Y1: Diagnostic output OUT from sensor 4 [3] Terminals Y2+Y3, Y4+Y5, Y6+Y7 are bridged when delivered Operating Manual PSEN ix2 F4 code 1003823-EN-02...
  • Page 7: Safety

    "System Description Safety Device Diagnostics". Series connection of PSEN sensors and connection to an evaluation device A max. of 4 PSEN sensors can be connected to a PSEN ix2 F4 code. All sensors must be 8-pin, with 2 safety inputs each.
  • Page 8: Warranty And Liability

    (e.g. Electrical and Electronic Equipment Act). Function description With the help of the PSEN ix2 F4 code, Pilz sensors can be connected in series and con- nected to a fieldbus module for evaluation of diagnostics data. PSEN ix2 F4 code can also be connected in series.
  • Page 9: Installation

    PSEN 1 OUT 1 OUT 2 The diagnostic data from the sensors connected to the PSEN ix2 F4 code can be read and entered at terminal block X3. Installation The unit should be installed in a lockable control cabinet with a protection type of at least IP54.
  • Page 10: Wiring

    Input channel 2 of sensor White 24 VDC Brown 0 VDC Blue Signal output/diagnostic output Y32 of Grey sensor Signal input/diagnostic input Y1 of sensor Output channel 1 of sensor Green Output channel 2 of sensor Yellow Operating Manual PSEN ix2 F4 code 1003823-EN-02...
  • Page 11 Status of signal output/dia- gnostic output of PSEN 2 Status of signal input/diagnostic input of PSEN 2 Status of signal output/dia- gnostic output of PSEN 1 Status of signal input/diagnostic input of PSEN 1 Power supply Supply voltage + 24 V Brown Operating Manual PSEN ix2 F4 code 1003823-EN-02...
  • Page 12: Connection To Evaluation Devices

    PSEN 4: Terminal block X2, terminals 21-28 Connecting fewer than four sensors If fewer than four sensors are connected to a PSEN ix2 F4 code, the free sensor ter- minals on terminal blocks X1 and X2 must be bridged. –...
  • Page 13 Fig.: Terminal block X1 with three bridges for an unconnected sensor Connection without fieldbus module If the PSEN ix2 F4 code will not be connected to a fieldbus module, the bridges that are inserted on terminals X3 Y2 – X3 Y7 when the PSEN ix2 F4 code is delivered must all be removed.
  • Page 14: Series Connection Of The Interface

    Max. 5 PSEN ix2 F4 code can be connected in series. Max. 16 sensors can be connected to a fieldbus module. Only three sensors can be connected to the first PSEN ix2 F4 code devices. 4 sensors can be connected to the final PSEN ix2 F4 code device.
  • Page 15 PSEN ix2 F4 code Sensor 1 Evaluation device Sensor 2 Sensor 3 Fieldbus module Sensor 4 Sensor 5 Sensor 6 Sensor n-3 Sensor n-2 Sensor n-1 Sensor n Operating Manual PSEN ix2 F4 code 1003823-EN-02...
  • Page 16: Dimensions

    Approvals UL/cUL Electrical data Internal resistance 0 Ohm Rated voltage Voltage UB 30 V Kind Environmental data Ambient temperature Temperature range -10 - 55 °C Storage temperature Temperature range -25 - 70 °C Operating Manual PSEN ix2 F4 code 1003823-EN-02...
  • Page 17: Order Reference

    540 320 10 m 540 321 20 m 540 333 30 m 540 326 PSEN cable M12‑8af Angled, M12, 8-pin, socket Open cable 540 322 540 323 10 m 540 324 30 m 540 325 Operating Manual PSEN ix2 F4 code 1003823-EN-02...