PSEN ix2 F4 code
Internal wiring diagram
The diagnostic data from the sensors connected to the PSEN ix2 F4 code can be read and
entered at terminal block X3.

Installation

}
The unit should be installed in a lockable control cabinet with a protection type of at
least IP54.
}
Use the notch on the rear of the unit to attach it to a DIN rail.
}
When installed on a vertical mounting rail (35 mm): Secure the unit by using a fixing
element (e.g. retaining bracket or end angle).
}
Circumvention of the safety switch in a reasonably foreseeable manner must be pre-
vented.
Operating Manual PSEN ix2 F4 code
1003823-EN-02
PSEN 4
X2
21
In1
22
In2
A1
23
24
A2
25
Y32
26
Y1
27
OUT 1
28
OUT 2
PSEN 3
X2
11
In1
12
In2
13
A1
14
A2
15
Y32
16
Y1
17
OUT 1
18
OUT 2
PSEN 2
X1
21
In1
22
In2
23
A1
24
A2
25
Y32
26
Y1
27
OUT 1
28
OUT 2
PSEN 1
X1
11
In1
12
In2
13
A1
14
A2
15
Y32
16
Y1
17
OUT 1
18
OUT 2
X3
X3