PSEN ix2 F4 code
Fig.: Terminal block X1 with three bridges for an unconnected sensor
Connection without fieldbus module
}
If the PSEN ix2 F4 code will not be connected to a fieldbus module, the bridges that are
inserted on terminals X3 Y2 – X3 Y7 when the PSEN ix2 F4 code is delivered must all
be removed. The respective states of the sensors' signal input/diagnostic input Y1 and
signal output/diagnostic output Y32 are output at these terminals. To evaluate the data,
the relevant control system must be connected to the terminals (see diagram).
Operating Manual PSEN ix2 F4 code
1003823-EN-02
X1
21 22
Terminals Y1, Y3, Y5, Y7 for the sensors' signal output/diagnostic output Y32
Terminals Y2, Y4, Y6, Y8 for the sensors' signal input/diagnostic input Y1
X3
Y1 Y2
Y1 Sensor 4
Y32 Sensor 4
Sensor 1
Sensor 2
Sensor 3
Sensor 4
23
24
25
26
Y3 Y4 Y5 Y6 Y7 Y8
Y32 Sensor 1
Y1 Sensor 2
Y32 Sensor 2
Y1 Sensor 3
Y32 Sensor 3
O2
X1
O1
I2
I1
A2
A1
X3
X2
Y1
Y8
27
28
Y1 Sensor 1
I2
Evaluation device
I1
O2/A1
O1/A1
A2
A1
Rx
Fieldbus module
Tx
13