PSEN ix2 F4 code
Fig.: Terminal block X1 with three bridges for an unconnected sensor
Connection without fieldbus module
}
If the PSEN ix2 F4 code will not be connected to a fieldbus module, the bridges that are
inserted on terminals X3 Y2 – X3 Y7 when the PSEN ix2 F4 code is delivered must all
be removed. The respective states of the sensors' signal input/diagnostic input Y1 and
signal output/diagnostic output Y32 are output at these terminals. To evaluate the data,
the relevant control system must be connected to the terminals (see diagram).
–
–
Operating Manual PSEN ix2 F4 code
1003823-EN-02
X1
21 22
Terminals Y1, Y3, Y5, Y7 for the sensors' signal output/diagnostic output Y32
Terminals Y2, Y4, Y6, Y8 for the sensors' signal input/diagnostic input Y1
X3
Y1 Y2
Y1 Sensor 4
Y32 Sensor 4
Sensor 1
Sensor 2
Sensor 3
Sensor 4
23
24
25
26
Y3 Y4 Y5 Y6 Y7 Y8
Y32 Sensor 1
Y1 Sensor 2
Y32 Sensor 2
Y1 Sensor 3
Y32 Sensor 3
O2
X1
O1
I2
I1
A2
A1
X3
X2
Y1
Y8
27
28
Y1 Sensor 1
I2
Evaluation device
I1
O2/A1
O1/A1
A2
A1
Rx
Fieldbus module
Tx
13