Connection To Evaluation Devices; General; Independent Circuit - Pilz PSEN ix2 F4 code Operating Manual

Table of Contents

Advertisement

PSEN ix2 F4 code
Terminal
A2
I1
I2
O1
O2

Connection to evaluation devices

General

Independent circuit

Please note:
}
When connected to the PSEN ix2 F4 code, the sequence of the sensors must be main-
tained.
Connecting fewer than four sensors
}
If fewer than four sensors are connected to a PSEN ix2 F4 code, the free sensor ter-
minals on terminal blocks X1 and X2 must be bridged.
Operating Manual PSEN ix2 F4 code
1003823-EN-02
Device
Power supply
PSEN n
Evaluation device
NOTICE
Each time the cabling is changed during commissioning, trigger the safety
function of each sensor in the safety chain and check that the safety outputs
on the evaluation device react correctly.
PSEN 1: Terminal block X1, terminals 11-18
PSEN 2: Terminal block X1, terminals 21-28
PSEN 3: Terminal block X2, terminals 11-18
PSEN 4: Terminal block X2, terminals 21-28
Terminal blocks X1 and X2
Bridges between terminals 11 and 17, 12 and 18 and 15 and 16.
Bridges between terminals 21 and 27, 22 and 28 and 25 and 26.
The terminals on terminal blocks X1 and X2 must be bridged for each unconnected
sensor (see diagram).