MODBUS REGISTER ADDRESSES LIST
Readable Parameters: [Length (Register): 2; Data Structure: Float]
Address
Hex Address
30000
0x00
30002
0x02
30004
0x04
30006
0x06
30008
0x08
30010
0x0A
30012
0x0C
30014
0x0E
30016
0x10
30018
0x12
30020
0x14
30022
0x16
30024
0x18
30026
0x1A
30028
0x1C
30030
0x1E
30032
0x20
30034
0x22
30036
0x24
30038
0x26
30040
0x28
30042
0x2A
30044
0x2C
30046
0x2E
30048
0x30
30050
0x32
30052
0x34
30054
0x36
30056
0x38
30058
0x3A
30060
0x3C
30062
0x3E
30064
0x40
30066
0x42
30068
0x44
30070
0x46
30072
0x48
30122
0x7A
30124
0x7C
30126
0x7E
30128
0x80
30130
0x82
30132
0x84
30134
0x86
30136
0x88
30138
0x8A
30140
0x8C
Parameter
Voltage V1N
Voltage V2N
Voltage V3N
Average Voltage LN
Voltage V12
Voltage V23
Voltage V31
Average Voltage LL
Current I1
Current I2
Current I3
Average Current
kW1
kW2
kW3
kVA1
kVA2
kVA3
kVAr1
kVAr2
kVAr3
Total KW
Total KVA
Total KVAr
PF1
PF2
PF3
Average PF
Frequency
Total net kWh
Total net kVAh
Total net kVArh
kW Max Active Power
kW Min Active Power
kVAr Max Reactive Power
kVAr Min Reactive Power
kVA Max Apparent Power
Neutral Current
THD of 1st Phase Voltage
THD of 2nd Phase Voltage
THD of 3rd Phase Voltage
THD of Voltage V12
THD of Voltage V23
THD of Voltage V13
THD of Current I1
THD of Current I2
THD of Current I3
Address
Hex Address
30684
0x2AC
30692
0x2B4
30694
0x2B6
30696
0x2B8
30698
0x2BA
30700
0x2BC
30702
0x2BE
30704
0x2C0
30706
0x2C2
30708
0x2C4
30710
0x2C6
30712
0x2C8
30714
0x2CA
30716
0x2CC
30718
0x2CE
30724
0x2D4
30726
0x2D6
Formula to fi nd address of individual Harmonic
Constant Parameter
0
1
2
3
4
5
6
7
8
{143 + [(Harmonic no-2) x 2] + 60 x Constant Parameter}
For Example,
To fi nd the 14th Harmonic address of Voltage V31 following
formula can be used:
Formula with the parameter:
{143 + [(Harmonic no-2) x 2] + 60 x C P}
Eg. {143 + [(14-2) x 2 ] + 60 x 5} = 467
So, Check the 14th Harmonic of Voltage V31 at 467 address.
Parameter
Serial no. (Data Structure: Hex)
MAX I1 Demand
MAX I2 Demand
MAX I3 Demand
MAX Avg. I Demand
Phase Sequence Indication
(0-OK Clockwise, 1-Anticlockwise,
2-Invalid)
Existing KW MAX Active Power
Existing KW MIN Active Power
Existing KVAr MAX Reactive Power
Existing KVAr MIN Reactive Power
Existing KVA MAX Apparent Power
Existing MAX I1 Demand
Existing MAX I2 Demand
Existing MAX I3 Demand
Existing MAX Avg. I Demand
DI Status
DI Count
Meaning
Voltage V1N
Voltage V2N
Voltage V3N
Voltage V12
Voltage V23
Voltage V31
Current I1
Current I2
Current I3