Siemens SMART 7KT Operating Instructions Manual page 6

Hide thumbs Also See for SMART 7KT:
Table of Contents

Advertisement

Confi guration (Continued)
There are 4 dedicated keys F1, F2, F3, F4. use these 4 keys to
enter into confi guration menu / change setting.
Note: The settings should be done by a professional, after
going through this users manual and after having understood
the application situation.
For the confi guration setting mode:
• Use F3 + F4 keys for 3 sec. to enter or exit from the
confi guration menu.
• Use F1 keys to move curser left or right by one digit each
time.
• Use F2 or F3 keys for increasing or decreasing parameters
value.
• Use F2 + F4 key to go back to previous page.
Confi g.
Function
page
Password
1
Change Password
1.1
New Password
2
Network
Selection
3
CT Secondary
4
Ct Primary
5
Pt Secondary
6
Pt primary
7
Slave Id
8
Baud Rate
9
Parity
10
Stop Bit
11
Back Light
12
Demand interval
method
13
Demand interval
duration
14
Demand interval
length
15
Max Page Auto
16
Change Page
Sequence
16.01
Page sequence 1
16.02
Page sequence 2
16.03
Page sequence 3
16.04
Page sequence 4
16.05
Page sequence 5
16.06
Page sequence 6
16.07
Page sequence 7
16.08
Page sequence 8
16.09
Page sequence 9
16.10
Page sequence 10
16.11
Page sequence 11
16.12
Page sequence 12
16.13
Page sequence 13
6
Factory
Range or Selection
Setting
0000 to 9998
No / Yes
0000 to 9998
3P4W, 3P3W, 1P2W-P1,
1P2W-P2 and 1P2W-P3
1A or 5A
1A, 5A to 10,000A
100V to 500V
100V to 500kV
1 to 255
300, 600, 1200, 2400,
4800, 9600 and 19200
(bps)
None, Odd, Even
1 or 2
0 to 7200 sec.
Sliding / Fixed
Sliding
1 to 30
1 to 30 min
1 to 22
No / Yes
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
Confi g.
Function
page
16.14
Page sequence 14
16.15
Page sequence 15
16.16
Page sequence 16
16.17
Page sequence 17
16.18
Page sequence 18
16.19
Page sequence 19
16.20
Page sequence 20
16.21
Page sequence 21
16.22
Page sequence 22
17
Factory default
18
Reset energy and
MAX demand
1000
18.1
Password
No
18.01
1)
Reset active
1000
energy
3P4W
18.02
Reset reactive
energy
5
18.03
Reset apparent
energy
5
18.04
Reset MAX
350
18.05
Reset ON hour
350
1
NETWORK SELECTION and WIRING INPUT
9600
Network selection in
confi guration mode
3P4W
None
3P3W
1
1P2W (P1/P2/P3)
0000
Note: P1, P2 and P3 are Three Phase.
1) For resetting energy parameters user will be prompted
the password. If correct password is entered, the user
15
will be able to reset all energy parameters. This password
will be value which will be greater than the confi guration
1
password by 1.
22
No
1
2
3
4
5
6
7
8
9
10
11
12
13
Factory
Range or Selection
Setting
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
1 to 22
No / Yes
No
No / Yes
No
0001 to 9999
1001
No / Yes
No
No / Yes
No
No / Yes
No
No / Yes
No
No / Yes
No
Wiring
3P4W, 2P3W
3P3W
1P2W (P1/P2/P3)
14
15
16
17
18
19
20
21
22

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7kt0310

Table of Contents