Notes:
Data, socket data receiving and sending status indicator, output high level when idle. When the socket receives
wireless data, the pin will continue to pull down 500ms. If there is wireless data coming within 500ms, it will
continue to pull down 500ms, If there is no data coming within 500ms, the high-level output will be restored; when
the socket sends data, it will continue to pull down 500ms; if there is data transmission within 500ms, it will
continue to pull down 500ms; if there is no data transmission within 500ms, the high-level output will be restored.
Link-B, socket1 connection status indicator, socke1 output high level when not connected, low level output after
successful connection, and high level output after disconnection.
LINK-A, socket0 connection status indicator, socke0 output high level when not connected, low level output after
successful connection, and high level output after disconnection.
IO_ Rst, restore the factory settings. This pin is pulled down for about 1 second. If the serial port returns to factory
reset, the factory settings will be restored and the automatic restart will take effect.

3 Ebyte extended command and function description

3.1 Ebyte transparent transmission application enable

AT command
AT+EBYTEAPP=<enable>\r\n
AT+EBYTEAPP
(1) This AT command configures whether to use TCP, UDP, Ebate Cloud, MQTT and COAP transparent transmission
applications. By default, AT+EBYTEAPP=1 is enabled. When you need to access the China mobile Onenet cloud,
Telecom CTWING cloud, AT+NSOCR AT+NSOCO AT+NSOST and other comamnd sets, you need to set
AT+EBYTEAPP=0 to close the transparent transmission application.
(2) Configuration parameter description:
< enable >: 0 means to close the transparent application, and 1 means to open the transparent application.
Note: When power-off saving is required, input AT+NRB command will save the parameters to flash, and automatically
restart to take effect.

3.2 Select the service to automatically connect after power-on

Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co., Ltd
Response
OK
Ebyte app enable: <enable>
OK