Check For Proper Operation - Cabletron Systems FRX6000 Installation & Setup Manual

Cabletron systems user guide smartswitch netlink frx4000, frx6000
Hide thumbs Also See for FRX6000:
Table of Contents

Advertisement

Configure the Token Ring Card
If the node has a Token Ring card, it is configured for a speed of 16 MB/sec and
UTP (unshielded twisted pair) cable. If you wish to change either setting,
follow this procedure:
1. Boot the node with a DOS system disk.
2. At the
prompt, insert the SMC SuperDisk, then type
A:>
. The EZStart main menu will be displayed, showing the current
[Enter]
configuration of any installed SMC Token Ring adapter(s).
3. If there are two Token Ring cards installed, select the adapter number
(
).
Select Adapter
4. Select
, then change the
Custom
5. When finished reconfiguring the card(s), remove the diskette.

Check for Proper Operation

This procedure requires a video device connected to the node.
1. Switch the node on and watch the power-up and boot messages for signs
of problems. A typical power-up sequence display will contain BIOS
copyright information followed by a System Configuration table: disk
drive types, base and extended memory, etc. A typical boot sequence will
include copyright information, debug messages, and messages tracking
the loading of RLPs.
Watch power-up and boot messages carefully—some errors will cause a
pause, but otherwise will not interfere with the boot process, and the only
way you will know there is a problem is to see the message as it is dis-
played. Be aware of messages that say:
message should appear for each installed RLP.
Some messages are written to a file called BOOTRPT.TXT.
Once the FRX6000 software is running, this file can be dis-
played. (See "Displaying Boot-up Information" on pge 11.)
Once the software has loaded, a screen similar to the following will be dis-
played.
Installation & Setup Guide
and press
ezstart
setting(s) as desired.
Network Interface
. Such a
Loading LP "n" - RLP
2. To log in, press
password when requested. (The default password when the software is
installed is
Menu (Figure 8) will be displayed.
9
10
Port Status Display (Page 1)
L P
Type
PPS Conn#
State
L P Type PPS Conn#
F1: Login
Figure 7 Port Status Display
at the Port Status Display, then enter the FRX6000
[F1]
.) Once the password has been entered, the Main
NETLINK
If the entered password is not correct, the Port Status Display
will reappear; if no password is entered, the Port Status Display
will reappear after a one minute timeout.
Node Name=
State
FRX6000

Advertisement

Table of Contents
loading

This manual is also suitable for:

Netlink frx4000

Table of Contents

Save Article as PDF