Hoffer Flow Controls HIT-4L User Manual page 36

Liquid flow rate indicator & dual totalizer with modbus & data logging
Table of Contents

Advertisement

30 Configuration
TABLE MENU
Menu
Item
RECAL
Restores K-Factor
table to factory
default values to
allow entry of new
calibration data.
POINTS
Number of points
FR 01
Frequency points
2 – 20. Follow
monotonic and
separation rules.
K 01
K factor points
2 - 20
MODBUS MENU
Menu Item
ADDRSS
Modbus address
BAUD
Baud rate for
RS485
*Not currently supported.
HP-329
Description
Description
Options
NO
YES
2-20
Numeric
Entry
5000.000
Numeric
Entry
9999999.9
Options
Numeric
000-254
entry
9600
*57600
*115200
Min
Default
Max
Value
N/A
NO
2
10
20
0.001
Fr20 =
5000.000
Fr19=
4999.999
Fr18
=49999.998
ETC.
0.001
1.000
Min
Default
Max
Value
N/A
9600
HIT-4L