Polygroup SUMMER WAVES RX330 Owner's Manual

Polygroup SUMMER WAVES RX330 Owner's Manual

Cartridge filter pump
Hide thumbs Also See for SUMMER WAVES RX330:

Advertisement

Available languages

Available languages

OWNER'S MANUAL
SUMMER WAVES
®
CARTRIDGE FILTER PUMP
FOR ABOVE GROUND SWIMMING POOLS
Model RX330
READ AND KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
For answers to common questions, setup videos and troubleshooting tips, please visit
To order parts and accessories,
support.polygroupstore.com or call Customer Service: 1-888-919-0070
please visit www.polygroupstore.com
DO NOT RETURN PRODUCT TO STORE
Should you encounter a problem with your Polygroup
Product, please DO NOT return the product to the place of purchase. All warranty claims must
®
be made directly to Polygroup
. For any setup and troubleshooting issues, please visit support.polygroupstore.com. Customer Service: 1-888-919-0070.
®
You may be asked to return all or part of the product for inspection and/or repair. Do not return any product to Polygroup
without a Return
®
Merchandise Authorization number.
DISTRIBUTED BY: Polygroup
Trading Limited Unit 606, 6th Floor, Fairmont House, No.8 Cotton Tree Drive, Central, Hong Kong
®
Manual #
Should you encounter any problems, contact Customer Service at 1-888-919-0070 from 8AM to 5PM MST, Monday-Friday.
Extended operating days and hours during peak season requirements.
09C3A4USA037

Advertisement

Table of Contents
loading

Summary of Contents for Polygroup SUMMER WAVES RX330

  • Page 1 . For any setup and troubleshooting issues, please visit support.polygroupstore.com. Customer Service: 1-888-919-0070. ® You may be asked to return all or part of the product for inspection and/or repair. Do not return any product to Polygroup without a Return ®...
  • Page 2 Warranty claims cannot be processed without a valid proof of purchase. This Limited ® Warranty applies only to the original purchaser of the product and is limited solely to the repair or replacement of the product, to be decided in Polygroup ’s sole ®...
  • Page 3 CUSTOMERS WHO PURCHASE POOLS MAY BE REQUIRED BY LOCAL OR STATE LAW TO INCUR ADDITIONAL EXPENSES WHEN INSTALLING A POOL, IN ORDER TO COMPLY WITH STATE OR LOCAL LAWS REGARDING FENCING AND OTHER SAFETY REQUIREMENTS. CUSTOMERS SHOULD CONTACT THEIR LOCAL BUILDING CODE ENFORCEMENT OFFICE FOR FURTHER DETAILS. POLYGROUP IS NOT RESPONSIBLE FOR ANY ADDITIONAL EXPENSES THAT YOU MAY INCUR.
  • Page 4 Turn on the pump for the recommended hours daily. If you are unsure of the time frames please refer to support.polygroupstore.com for the recommended Pump Operation Hours based on pool types and sizes. Clean and replace filter cartridge frequently. Replace only with a genuine Polygroup / Summer Waves Brand filter cartridge.
  • Page 5 OWNER’S MANUAL First Aid 1. Keep a working phone and a list of emergency numbers near the pool. 2. Become certified in cardiopulmonary resuscitation (CPR). In the event of an emergency, immediate use of CPR can make a lifesaving difference. Special Warning 1.
  • Page 6 ASME American Society of Mechanical Engineers Two Park Avenue, New York NY 10016-5990 Contact: 800-843-2763 (U.S. & Canada) 973-882-1170 (outside North America) www.asme.org NSPI National Spa and Pool Institute (see APSP) UL Underwriters Laboratories 333 Pfingsten Road,Northbrook IL 60062-2096 Contact: 877-854-3577 or 847-272-8800 www.ul.com NSF NSF International P.O.
  • Page 7 ) or its latest approved edition. ® ® 3. This Filter Pump is manufactured by Polygroup and ETL control number 4000608 and 4006317 – double insulated and grounded – 120VAC 60Hz. All units must ® have a minimum of 105VAC to start and run properly.
  • Page 8 RETURN FITTING SUCTION FITTING...
  • Page 9 OWNER’S MANUAL...
  • Page 10 SETUP INSTRUCTIONS Before assembly, take a few minutes to identify and become familiar with all the parts. WARNING: CLIMBING HAZARD! PLEASE PREVENT CHILDREN FROM CLIMBING ON THE FILTER CANISTER TO GAIN ACCESS TO THE POOL. Suction & Return Fittings Installation 1.
  • Page 11 OWNER’S MANUAL 5. Install the Universal Adaptor onto the Suction Fitting , and connect the 6. Connect the Return Fitting to the Pump outlet with another Hose and one Clamp on each end. Suction Fitting to the Pump inlet with a Hose and one Clamp on each end. Before Using the Pump 8.
  • Page 12 USE OF PUMP 1. Plug the GFCI Power Cord Set to a properly grounded receptacle at least 15 feet (4.5m) away from the pool. How to use the GFCI plug 2. To turn on the Pump, press the RESET button of the GFCI Plug. 3.
  • Page 13 NEVER drop lumps or pellets of chemicals into the pool – this may present a hazard to the swimmers and/or damage your pool liner. 3. Clean your pool regularly with a garden-hose-powered vacuum from Polygroup or any pool supplies stores.
  • Page 14 PUMP DISASSEMBLY & STORAGE 1. Unplug the Pump from the power outlet. 2. For the Suction Fitting : seal it with the SF Cap For the Return Fitting : remove the RF Diverter , and seal it with the Service Plug 3.
  • Page 15 OWNER’S MANUAL STEP 2: Rotor Inspection/Replacement 1. To take out the Rotor Assembly , simply remove the Volute Cover Screws and pull it out from the Pump Body 2. Inspect the Rotor (see image below) to make sure that the Rotor Shaft, Magnet Axle, Impeller and other parts are intact. If either of them is broken, you can purchase a new Rotor Assembly from polygroupstore.com without having to replace the whole Pump.
  • Page 16 STEP 3: Pump Replacement/Reassembly 1. Lubricate the Canister Gasket , then insert it back into the groove at the bottom of the Canister 2. Attach the Rubber Nozzle to the outlet of the Motor Assembly Make sure the Gasket sits in place in the groove 3.
  • Page 17 OWNER’S MANUAL TROUBLESHOOTING GUIDE Problem Cause Solution A. Plug the GFCI Power Cord Set to a 3-wire grounded power outlet. Then press A. Not plugged in the RESET button to restart it. 1. Motor doesn’t start, B. GFCI Power Cord Set B.
  • Page 18 REPLACEMENT PARTS ORDERING INFO Description Part # Fitting Gasket (black) P58PF1520K01 P58281283W05 Suction Fitting (SF) P582812838UN P582812837CN P58PF1510K01 SF Washer P58PF15108UN P58PF15107CN P58PF1430W05 P58PF14308UN Fitting Lock Nut P58PF14307CN P58PF2820P01 SF Cap P58PF7800W05 P58PF78008UN Return Fitting (RF) P58PF78007CN P58PF7790W05 P58PF77908UN RF Diverter P58PF77907CN RF Service Plug P58PF0620K01...
  • Page 19 OWNER’S MANUAL ASME COMPLIANT SUCTION FITTING INFO PSF-100A and PSF-100B Suction Outlet Fitting (For Aboveground Pool) 1. PSF-100A and PSF-100B Suction Outlet Fitting are certified by IAPMO in accordance with the ASME/ANSI/APSP/ICC-16 2011 Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs. 2.
  • Page 21 . Si tiene dificultades con la instalación o desea saber más sobre cómo localizar y resolver problemas, visite ® support.polygroupstore.com. Atención al cliente: 1-888-919-0070. Puede ser necesario que nos envíe parte del producto o el producto en su totalidad para inspección y/o reparación. No devuelva ningún producto a Polygroup sin un número de autorización de devolución. ®...
  • Page 22 180 días desde la fecha de compra. El comprador original debe conservar el justificante de compra en forma de recibo de venta original de la tienda, que deberá presentar si así se lo solicita Polygroup o sus agentes delegados. Las reclama ciones de garantía no pueden procesarse sin ®...
  • Page 23 ADICIONALES AL INSTALAR UNA PISCINA, EN CUMPLIMIENTO DE LAS LEYES ESTATALES O LOCALES RELATIVAS AL VALLADO Y OTROS REQUISITOS DE SEGURIDAD. LOS CLIENTES DEBEN PONERSE EN CONTACTO CON LAS AUTORIDADES LOCALES CORRESPONDIENTES PARA MÁS INFORMACIÓN. POLYGROUP NO ES RESPONSABLE POR GASTOS ADDICIONALES QUE PUEDAN OCCURIR.
  • Page 24 Limpie y cambie el cartucho de la bomba del filtro con frecuencia. Reemplazar solo con un cartucho de filtro original de la marca Polygroup...
  • Page 25 MANUAL DEL USUARIO 3. Coloque los muebles (por ejemplo, mesas o sillas) lejos de la piscina para que los niños no puedan subirse a ellos para acceder a la piscina. Riesgo de electrocución 1. Mantenga los cables eléctricos, radios, altavoces y otros aparatos eléctricos legos de la piscina. 2.
  • Page 26 APSP Association of Pool & Spa Professionals (formerly National Spa and Pool Institute) 2111 Eisenhower Avenue, Suite 500 Alexandria VA 22314-4679 Contacto: 703-838-0083 www.apsp.org ASME American Society of Mechanical Engineers Two Park Avenue, New York NY 10016-5990 Contacto: 800-843-2763 (U.S. & Canada) 973-882-1170 (outside North America) www.asme.org NSPI National Spa and Pool Institute (see APSP) UL Underwriters Laboratories...
  • Page 27 MANUAL DEL USUARIO PASOS PRELIMINARES 1. LEA ATENTAMENTE TODAS LAS INSTRUCCIONES y comprenda bien lo que hace falta para montar la bomba de filtro. 2. Se recomienda tener algo de vaselina (no incluida) a la mano para lubricar los empaques y los anillos negros. IMPORTANTE: 1.
  • Page 28 ACCESORIO DE RETORNO ACCESORIO DE SUCCIÓN...
  • Page 29 MANUAL DEL USUARIO...
  • Page 30 INSTRUCCIONES DE MONTAJE Antes de ensamblar, tómese unos minutos para identificar y familiarizarse con todas las partes. ADVERTENCIA: COLOQUE ESTE PRODUCTO APARTADO DE LA PISCINA A FIN DE EVITAR QUE LOS NIÑOS SE SUBAN A ÉL Y ACCEDAN A LA PISCINA. Instalación de la boquilla de retorno y el accesorio de succión 1.
  • Page 31 MANUAL DEL USUARIO 5. Instale el adaptador universal en el accesorio de succión 6. Conecte la accesorio de retorno a la salida de la Bomba con otra conecte el accesorio de succión a la entrada de la bomba con manguera y una abrazadera a cada extremo. una manguera y una abrazadera en cada extremo.
  • Page 32 USO DE LA BOMBA 1. Enchufe el set de cable de alimentación GFCI a un tomacorriente correctamente puesto a tierra al menos a 15 pies (4.5 m) Cómo utilizar el tapón del GFCI de la piscina. 2. Para encender la Bomba, presione el botón RESET del enchufe GFCI. 3.
  • Page 33 CUIDADO DEL AGUA DE LA PISCINA, a continuación). 5. Elimine cualquier filtro usado en conformidad con las regulaciones/leyes correspondientes. ; se encuentran disponibles en la tienda donde ha comprado su piscina o en polygroupstore.com. 6. Siempre use Cartuchos de filtro Polygroup Summer Waves ®...
  • Page 34 DESMONTAJE Y ALMACENAMIENTO DE LA BOMBA DE LA PISCINA 1. Desenchufe la Bomba de la salida de alimentación. 2. Para el accesorio de succión : séllelo con la Tapa del SF Para la Accesorio de retorno : retire el Desviador de la RF y séllelo con al Tapón de servicio 3.
  • Page 35 MANUAL DEL USUARIO PASO 2: Inspección/Reemplazo del rotor 1. Para sacar el ensamblaje del rotor , simplemente retire los tornillos de la cubierta de la voluta y tire de él hacia afuera desde el motor 2. Inspeccione el Rotor (ver imagen a continuación) para asegurarse de que el Eje del rotor, el Eje del imán, el Impulsor y otras partes estén intactas. Si cualquiera de ellos está...
  • Page 36 PASO 3: Reemplazo/Reensamblaje de la Bomba 1. Lubrique el Empaque del cartucho , luego insértelo de regreso en la ranura en la parte inferior de la Caja 2. Fije la Boquilla de goma a la salida del montaje del motor Asegúrese que el empaque se asiente en su lugar en la ranura.
  • Page 37 MANUAL DEL USUARIO GUÍA DE RESOLUCIÓN DE PROBLEMAS Problema Causa Solución A. Enchufe el set de cable de alimentación GFCI a un tomacorriente de 3 hilos puesto a tierra. A. La unidad no está enchufada Luego presione el botón RESET para reiniciarla. 1.
  • Page 38 INFORMACIÓN SOBRE EL PEDIDO DE PIEZAS DE REPUESTO Clave Descripción N.º De Pieza Empaque de la boquilla (negro) P58PF1520K01 P58281283W05 Accesorio de succión P582812838UN P582812837CN P58PF1510K01 Arandela del SF P58PF15108UN P58PF15107CN P58PF1430W05 P58PF14308UN Contratuerca del accesorio P58PF14307CN P58PF2820P01 Tapa del SF P58PF7800W05 P58PF78008UN Accesorio de retorno...
  • Page 39 MANUAL DEL USUARIO INFORMACIÓN SOBRE LA CONFORMIDAD ASME DEL ACCESORIO DE SUCCIÓN PSF-100A y PSF-100B Orificio De Salida De Succión (Para Piscinas Sobre Suelo) 1. Los orificios de salida de succión PSF-100A y PSF-100B tienen la certificación de la IAPMO de acuerdo con la norma ASME/ANSI/APSP/ICC-16 2011 Accesorio de succión para piscinas, piscinas infantiles, spas y bañeras de hidromasaje.

Table of Contents