TROUBLESHOOTING
Problem
Flame is yellow or orange
Flame goes out
Flashback (fire in burner/
venturi
tube(s)
Flame seems to lose heat
when burning in cold
weather temperature
below 50°F
Manufacture : CHANGZHOU WELLIFE FURNACE CO.,LTD
Add:Liuxiang Village, Zouqu Town, Zhonglou District,Changzhou City,Jiangsu Province,CHINA.
Possible Cause
New burner may have residual
manufacturing oils
Spider webs or inset nest in
burner/venturi tube
Poor alignment of valve to
burner/venturi tube
High or gusting winds
L
o
w
o
n
L
P
g
a
s
Excess flow valve tripped
Burner and /or burner/venturi tube is
blocked
Ice has built up on the outside of the
LP gas tank because the
vaporization process is too slow.
Page 24 of 26
Prevention/Cure
Burn outdoor fire pit for 15 minutes and
inspect.
Clean burner/venturi tube
Ensure/burner/venturi tube is properly
engaged with valve
Do NOT use outdoor fireplace in high winds
E
c x
h
a
n
g
, e
e r
l l i f
r o
e r
p
a l
Refer to "Sudden drop in gas flow or
reduced flame height"
Clean burner and /or burner/venturi tube
1. Turn LP gas tank valve "OFF" .
2.Turn control knob to "OFF".
3. Replace with a spare LP gas tank.
4. Reconnect LP gas tank per "Installing LP
gas tank" section.
5. Follow "Checking for leaks" section.
6. Light outdoor fire place per "Lighting"
section.
c
e
L
P
g
a
s
a t
n
k
Need help?