5.3. Electrode aging
The electrodes arc begins unstably when the external environment such as the temperature and
pressure changed greatly especially moving the machine from low altitude to high altitude. When
happened, users should take an electrode aging to stabilize the electrodes arc. The machine runs 5
times of huge electrodes arc when the user selects the electrodes aging and executes it.
Note: Please according to prompts to operate, do not open the cover while electrodes aging.
5.4. Software upgrade
The user should insert the USB disk with upgrade file into USB interface before software upgrade.
When the software upgrade menu is selected and pressed, the machine will automatically complete
the upgrading. After upgrading, the user should restart the machine.
1. Copy the upgrade document named "boot.dat" to the U-Disk, whose capacity must be more than
2GB.
2. Insert U-Disk into the USB interface of the machine.
3. Power on the machine. Press the menu button " ", entering the main menu.
4. Select the option "Function", and press button " ".
5. Select the option "Software upgrade" in the interface of Function, and press the button " ",
upgrade beginning.
6. After upgraded, pull out U-Disk, and restart machine.
USER MANUAL HANDHELD FTTX FUSION SPLICER FUSION SPLICER 4.3