Raid Support; Light-Guided Diagnostics - Intel E39545-004 Service Manual

Workstation board
Table of Contents

Advertisement

Callout
LED
H.
DIMM B1 fault LED
I.
DIMM B2 fault LED
J.
DIMM A1 fault LED
K.
DIMM A2 fault LED
L.
Processor 2 fan
fault LED
M.
DIMM D2 fault LED
N.
DIMM D1 fault LED
O.
DIMM E2 fault LED
P.
DIMM E1 fault LED
Q.
DIMM F2 fault LED
R.
DIMM F1 fault LED
S.
+5-V Standby LED

RAID Support

®
The Intel
Workstation Board S5520SC provides an embedded SATA controller that supports both 1.5 Gbps and 3.0 Gbps
data transfer rates.
The BIOS Setup Utility provides drive configuration options on the Advanced | Mass Storage Controller Configuration setup
page, some of which affect the ability to configure RAID. The "On-board SATA Controller" option is enabled by default and
when enabled, you can set the "SATA Mode" option to one of the following four modes:
"Enhanced" – Enhanced Mode supports up to six SATA ports with IDE native Mode.
"Compatibility" – Supports up to four SATA ports [0/1/2/3] with IDE Legacy mode and two SATA ports [4/5] with IDE
Native Mode.
"AHCI" – Supports all SATA ports using the Advanced Host Controller Interface.
"SW RAID" – Intel
Server RAID Technology II feature provides RAID modes 0, 1, and 10.
If RAID 5 is needed, you must install the optional Intel
placed on the SATA_ RAID_5_Key connector located on the left side of the workstation board. For installation instructions,
see the documentation included with the activation key.
Intel® Workstation Board S5520SC Service Guide
Functions
This LED indicates a fault occurred with the DIMM installed in socket DIMM_B1.
Replace the faulty DIMM
This LED indicates a fault occurred with the DIMM installed in socket DIMM_B2.
Replace the faulty DIMM.
This LED indicates a fault occurred with the DIMM installed in socket DIMM_A1.
Replace the faulty DIMM.
This LED indicates a fault occurred with the DIMM installed in socket DIMM_A2.
Replace the faulty DIMM.
This LED applies only to workstation systems that use an active heatsink. This LED
indicates a fault occurred with the fan installed on the heatsink for processor 2.
Replace faulty unit.
This LED indicates a fault occurred with the DIMM installed in socket DIMM_D2.
Replace the faulty DIMM.
This LED indicates a fault occurred with the DIMM installed in socket DIMM_D1.
Replace the faulty DIMM.
This LED indicates a fault occurred with the DIMM installed in socket DIMM_E2.
Replace the faulty DIMM.
This LED indicates a fault occurred with the DIMM installed in socket DIMM_E1.
Replace the faulty DIMM.
This LED indicates a fault occurred with the DIMM installed in socket DIMM_F2.
Replace the faulty DIMM.
This LED indicates a fault occurred with the DIMM installed in socket DIMM_F1.
Replace the faulty DIMM.
This LED is green whenever AC power is applied to the system. The system does not
need to be powered on for this LED to be on.
Figure 5. Intel
®
Embedded Server RAID Technology II is enabled by "SW RAID" mode. The Intel
®

Light-Guided Diagnostics

®
RAID Activation Key AXXRAKSW5 accessory. This activation key is
Workstation Board Features
®
Embedded
17