Starting Adjustment Program (Map) - Hitachi DZMV238EAU Service Manual

Dvd video camera/recorder
Hide thumbs Also See for DZMV238EAU:
Table of Contents

Advertisement

3.

Starting Adjustment Program (MAP)

The adjustment program will not start or operate normally unless the DVD video
camera/recorder, PC, jig and test equipment are correctly connected, and power
is supplied to each unit: Check the connections referring to "2.1 Connections for
adjustment", and then supply power to the DVD video camera/recorder, PC, jig
and test equipment.
1) Operate the PC to start MS-DOS (*1). (See MS-DOS screen 1.)
2) Make sure that the adjustment floppy disk is write-protected.
3) Insert the adjustment floppy disk into the floppy disk drive of PC.
4) Use the PC keyboard to type A:, and then press the Enter key (*2). (See the
MS-DOS screen 2.)
5) Type MAP_IBM (space) 1, and then press the Enter key (*3). (See the MAP
input screen.)
6) Make sure that the model select screen appears on the PC display (*4).
(See the model select screen.)
7) If the appropriate model is displayed on the model select screen, input the
number to PC. If the appropriate model name is not shown on the model
select screen, input P to PC until the model name appears (*5).
8) The screen for verifying the model name will appear on PC display: If it is
correct, input Y to PC. If it is incorrect, input N and start over from step 7.
9) Make sure that the main menu appears on PC display: If it does not appear,
check whether model selection (in step 7) is correct.
*1: For details on how to start MS-DOS, refer to the instruction manual of PC or
OS, since this varies for each PC.
*2: The letter to be input designates the drive into which the adjustment floppy
disk has been inserted. If using a drive other than A, designate that drive.
*3: The number to be input after space designates the serial port number of PC.
If the PC has two or more serial ports, and the RS-232C cable (DSP-R jig) is
connected to a port other than serial port 1, input that serial port number.
*4: If the model select screen does not appear, make sure of the following:
The designation of drive in step 4 is correct.
The designation of serial port in step 5 is correct.
The correct adjustment floppy disk has been normally inserted.
*5: If an erroneous model name or number is input, misoperation message will
appear on PC display: Press any key to restore the model select screen and
start over.
To terminate the adjustment program (MAP):
Press the Esc key one to three times until the PC display returns from a
menu screen to the MS-DOS screen.
When the MS-DOS screen appears on PC display, turn off the camera/
recorder and jig.
3 - 12
MS-DOS screen 1
C>
Insert adjustment floppy disk into PC.
Input A: to PC and press Enter key.
MS-DOS screen 2
C>A:
A>
Input MAP_IBM (space) 1 to PC.
MAP input screen
C>A:
A>MAP_IBM 1
Press Enter key on PC.
Model select screen
***********************************************************
MODEL SELECT
***********************************************************
[1]
××××××××
[2]
××××××××
[3]
××××××××
[4]
××××××××
[5]
××××××××
[P]
NEXT SELECTION
[ESC] END
Please select the type of the set
Press [1] - [5] or [P] or [ESC]
Select model (input the corresponding
number)
Screen for verifying model name
Selected model is ××××××××
Are you sure ? (Y/N)
Input Y to PC.
Main menu screen
***********************************************************
MANUAL ADJUSTMENT PROGRAM
***********************************************************
[A]
DATA INITIALIZE
[B]
CAMERA ADJUSTMENT
[C]
AUTO FOCUS
[D]
STABILIZER
[E]
SPOT NOISE
[ESC] END
Please select [A] - [E] or [ESC]
Reference: Misoperation message screen
CAN NOT FIND THE DATA FILE
**** PRESS ANY KEY ****