Default Values

USB-KBD DEFAULT SETTINGS
USA keyboard, FIFO enabled, inter-character and inter-code delays disabled, USB
keyboard speed normal.
: code identifier disabled, no field adjustment, code length not
DATA FORMAT
transmitted, no header, terminator = ENTER, character replacement disabled.
RS-232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx
timeout 5 sec., ack/nack disabled, FIFO enabled, inter-character delay disabled,
serial trigger lock disabled.
: code identifier disabled, no field adjustment, code length not
DATA FORMAT
transmitted, no header, terminator = CR-LF, character replacement disabled.
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, caps lock auto-recognition enabled, num lock
unchanged, inter-character and inter-code delays disabled, control character
emulation = ctrl+shift+key.
: code identifier disabled, no field adjustment, code length not
DATA FORMAT
transmitted, no header, terminator = ENTER, character replacement disabled.
PEN DEFAULT SETTINGS
interpret operating mode, conversion to code 39 disabled, output level normal,
idle level normal, minimum output pulse 600 μs, overflow medium, inter-block
delay disabled.
CODE SELECTION
Enabled codes
·
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
·
Interleaved 2/5
check digit control and transmission, variable length code; 4-99 characters
·
Standard Code 39
no check digit control, variable length code; 1-99 characters
·
Code 128
variable length code; 1-99 characters
Disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI, Code 11,
Code 16K, Code 49, GS1 DataBar™ Codes