General Description; Model Identification; 1.3 Serial Number Date Code - Airxcel Industrial Climate Engineering CFA1012A Installation & Operation Manual

Vertical air conditioners
Table of Contents

Advertisement

Chapter 1 Description & Specifications
1.1

General Description

The ICE CFA1012A line of environmental control units (ECU) is designed for the telecommunication
cabinet and shelter. Below are some of the features of the unit.
• The CFA1012A is available in a cooling capacity of 12,000 BTUH.
• Cabinet has powder coated finish for long term durability.
• Dry contacts are available for remote monitoring of lockout due to a high or lower pressure.
• Low ambient operation provided by condenser fan cycle control.
• 3.6 kW electric strip heat is standard.
• The ICE CFA1012A is safety listed by ETL. All units are manufactured and tested to UL 1995
current edition and CAN/CSA-C22.2 No. 236 2nd Ed.
The operating functions of the CFA1012A line are described below.
Cooling - Mechanical cooling is provided.
Heating - A 3.6 kW electric resistant heater (standard) operates to provide heating as required.
1.2

Model Identification

The model identification number is found on the data sticker. Rating plate located on side panel.
Example
C
F
A
1
Position
1
2
3
4
1
Unit Designation/Family
2
Energy Efficiency Ratio (EER) F = EER <9
3
Refrigerant Type
4
Compressor Type/Quantity
5
Unit Capacity/Nominal
6
Cooling (BTUH)
7
8
System Type
9
Power Supply (V-Ph-Hz)
10 Heat Designation
11
@ Rated Voltage
KW = Kilowatt
12
13 Ventilation Configuration
14 Dehumidification
15 Controls
16
Operating Condition

1.3 Serial Number Date Code

A = January
E = May
B = February
F = June
C = March
G = July
D = April
H = August
0
1
2
A
A
0
3
5
6
7
8
9
10
11
C = Industrial Climate Engineering (ICE)
A = R-410a
1 = Single
012 = 12,000
A = Air Conditioner
A = 208/230-1-60
036 = 3.6KW
A = Solid Front Door
+ = None
+ = None
1 = Low Ambient w/FCC
J = September
K = October
L = November
M = December
6
A
+
+
1
+
3
12
13
14
15
16
17
18
Indoor Air Quality
17
Features
18
Air Flow
Compressor
19
Location
20
Filter Option
21
Corrosion Protection
22
Engineering
Revision Level
23
24
Cabinet Color
25
Sound Attenuation
26
Security Option
Fastener/Drain Pan
27
Option
28
Unused
29
Unused
30
Special Variation
D = 2014
E = 2015
F = 2016
5
D
A
+
A
1
1
+
19
20
21
22
23
24
25
+ = None
3 = Bottom Supply/Top Return (Counter)
D = Left Hand
A = 2" Pleated (MERV 8)
+ = None
A1
1 = Beige
+ = None
+ = None
+ = None
+ = None
+ = None
+ = None
ICE CFA1012A I&O Manual 01/2021 New
+
+
+
+
+
26
27
28
29
30

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Industrial Climate Engineering CFA1012A and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents