These instructions are a general guide for installing the 45000 Series Coleman-Mach roof top air conditioners. For
specific air conditioner details, it will be necessary to refer to ALL printed documents supplied with this air conditioner.
These instructions are for the use of qualified individuals specially trained and experienced in installation of this type
equipment and related system components.
Installation and service personnel are required by some states to be licensed. PERSONS NOT QUALIFIED SHALL
NOT INSTALL NOR SERVICE THIS EQUIPMENT.
NOTE: The words "Shall" or "Must" indicate a requirement which is essential to satisfactory and safe product
performance. The words "Should" or "May" indicate a recommendation or advice which is not essential and not
required but which may be useful or helpful.
WARNING! - SHOCK HAZARD To prevent the possibility of severe personal injury or equipment damage due
to electrical shock, always be sure the electrical power source to the appliance is disconnected.
CAREFULLY FOLLOW ALL INSTRUCTIONS AND WARNINGS IN THIS BOOKLET TO AVOID DAMAGE TO
WARNING! Improper installation may damage equipment, can create a hazard and will void the warranty.
The use of components not tested in accordance with these units will void the warranty, may make the equipment
in violation of state codes, may create a hazard and may ruin the equipment.
P/N: 1980A036, Rev. 2
INSTALLATION, OPERATION
IMPORTANT NOTICE
THE EQUIPMENT, PERSONAL INJURY OR FIRE.
IX.
3
3
ii.
3
iii.
3
iv.
3
v.
5
vi.
5
X.
5
8
XI.
8
1
10
10
10
12
12
13
13
27
28
08-04-2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Coleman-Mach 45000 Series and is the answer not in the manual?

Questions and answers

Steve
June 4, 2025

How do you keep the capillary wire attached to the evaporater

Subscribe to Our Youtube Channel

Summary of Contents for Airxcel Coleman-Mach 45000 Series

  • Page 1: Table Of Contents

    INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR 45000 SERIES AIR CONDITIONERS TABLE OF CONTENTS Operation and Maintenance General Information General Information Air Conditioner Sizing Control Panel III. Selecting an Installation Location iii. Operation Installing the Roof Top Unit Maintenance Wall Thermostat Identification and Standard Installation Operation OEM Top/Down Mounting...
  • Page 2: General Information

    III. SELECTING AN INSTALLATION LOCATION around the roof opening to obtain clean exterior Your Airxcel, Inc. air conditioner has been designed for roof surface. use primarily in recreational vehicles. b. It may be necessary to seal some of the old roof...
  • Page 3 (See Airxcel, Inc. requires that the spacing from the vehicle Figure 4). The upper unit has now been properly roof top to the interior ceiling be no less than 1”. A installed with optimum gasket compression.
  • Page 4: Oem Top/Down Mounting

    WIRE). INSERT THE SUPPLY WIRES INTO THE sizing. The OEM ducting requirement document is ELECTRICAL CONNECTOR CLAMP. SHEATH available at www.AIRXCEL.com. The rooftop unit must MUST PROTRUDE PAST THE CLAMP BUSHING be mounted as near to level from front to rear and side INSIDE THE BOX.
  • Page 5 Figure 4 REFER TO OEM DUCTING REQUIREMENTS FOR SUPPLY AND RETURN DUCTING INFORMATION. OEM DUCTING REQUIREMENT IS AVAILABLE AT www.AIRXCEL.com. IT IS THE RESPONSIBILTY OF THE INSTALLER TO PROVIDE THE MEANS FOR SEGREGATION OF SUPPLY AND RETURN AIR. Figure 5...
  • Page 6 FIGURE 6 FIGURE 7 FIGURE 8 FIGURE 9 FIGURE 10...
  • Page 7: Installing Ceiling Assembly

    E. Press supply conductors and wire nuts into VIII. SYSTEM CHECKOUT wiring box and making sure no wires are Airxcel, Inc. manufactures a wide range of roof top pinched, secure the wire box cover with 2 air conditioners which incorporate different product provided screws (See Figure 10).
  • Page 8 Apply today by filling out the application located on the back cover of this Installation and Operation Manual and mailing it in along with your check or money order for $89.95 to Airxcel, Inc., P.O. Box 4020, Wichita, KS 67204. A contract will be sent to you within a few weeks.
  • Page 9: Operation And Maintenance

    OPERATION AND MAINTENANCE INSTRUCTIONS FOR 45000 SERIES ROOF TOP AIR CONDITIONERS AND CEILING PLENUM GENERAL INFORMATION NOTE: The optional Elect-A-Heat heating assembly is This roof mount air conditioner is designed to operate intended to take the chill out of the indoor air when the from a 115 VAC, 60 HZ, 1 Phase power supply.
  • Page 10 Figure 1 Figure 2...
  • Page 11: Operation

    iii. OPERATION unit drops below this setting a few degrees and I. For Cooling (Refer to Figure 1, page 10). automatically turns off when the temperature of the A. Turn the selector switch to the “LOW COOL” or air entering the air conditioner rises a few degrees “HIGH COOL”...
  • Page 12: Wall Thermostat Identification And Operation

    Service Center if electrical problems should arise. locations. B. Check Points – Failure to start or to cool the air Airxcel, Inc. support help may be accessed by e-mail are sometimes problems with air conditioner at RVPSupport@Airxcel.com. All written units. The Coleman-Mach RV air conditioner is correspondence should be directed to: designed to operate on 115 volt electrical power.
  • Page 13 CLIMATISEURS SÉRIE 45000 INSTRUCTIONS POUR INSTALLATION ET LE FONCTIONNEMENT ET D’ENTREITIEN TABLE DES MATIERES Opération et maintenance Informations générales Informations générales Sélection d’un climatiseur approprié Panneau de Controle Sélection de l’emplacement iii. III. Functionnement d’installation Installation de l’unité de toit Entretien Identification et functionnement du Installation Standard...
  • Page 14: Informations Générales

    à votre représentant l’emplacement des évents de toit existants. En absence Airxcel ou à Airxcel devraient contenir le nom et le d’un évent de toit (ouverture d’installation existante), numéro de série du modèle du climatiseur. Le nom et nous recommandons les endroits ci-dessous.
  • Page 15: Installation Standard

    (14 po à 15 po) dans le toit. La série 45000 d’Airxcel exige un écart minimum de b. Installez le cadre de montage de l’ensemble de 2,54 cm (1 po) entre le toit du véhicule et son plafond plafond à...
  • Page 16 Figure 1 Figure 2 Figure 3...
  • Page 17: Oem Haut / Bas De Montage

    ACHEMINEMENT DU CÂBLAGE 115 V CC haut en bas, le toit du véhicule doit être conçu pour En respectant les spécifications d’Airxcel, Inc. pour le supporter de manière adéquate et fixer solidement câblage haute tension et l’ensemble des codes de l’unité...
  • Page 18 SE RÉFÉRER AUX EXIGENCES DE CONDUITES OEM POUR LES INFORMATIONS D'ALIMENTATION ET DE CONDUITES DE RETOUR. LE DOCUMENT D'EXIGENCE DE CONDUITES OEM EST DISPONIBLE SUR www.AIRXCEL.com. IL EST DE LA RESPONSABILITÉ DE L'INSTALLATEUR DE FOURNIR LES MOYENS DE SÉPARATION DE L'APPROVISIONNEMENT ET DU RETOUR D'AIR.
  • Page 19 Figure 7 Figure 8 Figure 9 Figure 10...
  • Page 20: Installation De L'accessoire De Chauffage Facultatif

    climatiseur, tel qu’illustré dans la Figure 7. Le support Spécification de câblage de câblage électrique à haute tension est basée sur la protection contre les de réchauffeur doit être installé par-dessus le bac à surintensités Appareil nominale plus élevée que le condensation métallique extrudé...
  • Page 21: Vérification Fonctionnelle Du Système

    L. Installez les boutons de commande sur les tiges de VIII. VÉRIFICATION FONCTIONNELLE DU commutateur et de thermostat. Le bouton de SYSTÈME commande de thermostat (température) s’installe Airxcel, Inc. fabrique une gamme étendue de immédiatement à côté du logo « Coleman-Mach ». climatiseurs toit incorporent différentes...
  • Page 22 Postulez dès aujourd’hui en remplissant le formulaire situé sur la couverture arrière de cette installation et d’utilisation et en l’envoyant dans le long avec votre chèque ou mandat à Airxcel, Inc., PO Box 4020, Wichita, KS 67204. Un contrat sera envoyé à...
  • Page 23: Panneau De Controle

    IX. MODE D’EMPLOI ET UTILISATION SÉRIES 45000 DES CLIMATISEURS DE TOIT DES PLÉNUM DE PLAFOND i. RENSEIGNEMENTS GÉNÉRAUX du véhicule un peu trop frais pour le confort. Le Ces climatiseurs de toit furent conçus pour fonctionner système de chauffage est efficace pour «enlever le à...
  • Page 24: Entretien

    iii. FONCTIONNEMENT chauffage est efficace pour «enlever le froid», mais non pas pour remplacer l’appareil de chauffage. I. Pour le refroidissement Ne pas s’attendre à ce que le serpentin de chauffage (se reporter aux figure 1, page 23). votre appareil chauffage produise A.
  • Page 25: Identification Et Functionnement Du

    électriques ne doivent être effectués que par un suivante: personnel d’entretien qualifié. Contactez votre AIRXCEL, INC. - RV Products Division centre d’entretien Airxcel, Inc. s’il y a des problèmes. P.O. Box 4020 B. Points de contrôle – Les climatiseurs ont quelquefois Wichita, KS 67204 des problèmes de démarrage ou de refroidissement.
  • Page 26 Figure 2...
  • Page 27: Serial Number Nomenclature

    X. SERIAL NUMBER NOMENCLATURE X. SERIAL NUMBER NOMENCLATURE The serial number format from March 2020 to present is: the first 2 digits signify the production year, the last 7 years are sequential production numbers (random number) EXAMPLE: 20XXXXXXX XXXXXXX Year 7 random (2020) numbers...
  • Page 28: Optional Extended Warranty

    Apply today by filling out the application below and mailing it with your check or money order for $89.95 to Airxcel, Inc., P.O. Box 4020, Wichita, KS 67204. A contract will be sent to you within a few weeks. You should retain with your paperwork for proof of purchase.

Table of Contents

Save PDF