Height Error Sensor Q29 - Plockmatic FeederPro 1000 Service Manual

Hide thumbs Also See for FeederPro 1000:
Table of Contents

Advertisement

2.12Height Error Sensor Q29

The purpose of the sensor is to prevent machine from breaking. When liftmotors are activated and not
stopped by empty bin sensor, before reaching mechanical stop, height error sensor will be activated. When
height error sensor is activated it will shut off power to the liftmotors.
REMOVAL
1.
Open Rear Door according to REP 2.4
2.
Go to service meny, RUN MOTORS, see chapter 4, and lift above bin for better access.
3.
Remove sensor.
REPLACEMENT
1.
Installation is an exact reversed procedure of removal.
FEEDER PRO MODEL 1000
PAGE 17
T08093
MARCH-05

Advertisement