Troubleshooting - Bristan Cheer CHE85 W Installation Instructions And User Manual

Electric shower
Table of Contents

Advertisement

Troubleshooting

Symptom
No water flow.
Water temperature too
hot.
Shower runs hot and cold
during use.
Shower temperature
cycles between hot and
cold.
Water from pressure
relief outlet-PRD
activated.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Likely Cause(s)
Water isolating valve in off position.
Filter blocked.
Outlet hose mesh filter blocked.
Power supply not on.
Insufficient water flowing
through the shower.
Water pressure is at minimum
requirement.
Shower temperature is set too high
causing the thermal cut out to turn off
the heating elements to reduce the
water temperature.
Obstruction in hose or handset.
Action/Remedy
Turn on.
Turn off water supply, remove filter
and clean.
Remove the outlet hose from the shower, remove mesh
filter and clean.
Turn on.
Clean the handset.
Increase the flow by adjusting the temperature control
knob to cooler setting.
Reduce the power setting.
Check running pressure (minimum of 0.7bar).
Wait until pressure increases.
Turn shower temperature control anti-clockwise to
reduce the water temperature.
Call Customer Services.