Troubleshooting - Bristan TFP4001 Installation Instructions Manual

Timed flow shower panel with adjustable head
Table of Contents

Advertisement

Troubleshooting

Symptom
Symptom
Symptom
Symptom
Shower will not
turn on when
push button is
pressed in.
Shower will not
turn off.
Shower does not
run for long
enough.
Need help?
Need help? Give us a call on 0844 701 6273
Need help?
Need help?
Cause
Cause
Cause
Cause
Isolation valve closed.
Bleed tube not fitted correctly.
Shower flow cartridge faulty.
Push button assembly faulty.
Shower flow cartridge faulty.
Push button assembly faulty.
Isolation valve partially closed.
Insufficient water pressure.
Shower flow cartridge faulty.
0844 701 6273 and speak to one of our trained advisors.
0844 701 6273
0844 701 6273
Remedy
Remedy
Remedy
Remedy
Open the isolation valve on the
telescopic connection.
Check any isolation valves to the
water supply are open.
Remove the shower panel from
the wall and check the bleed
tube is fitted correctly.
Remove the shower flow
cartridge and check / replace if
necessary. Refer to maintenance
section (pages 15-16).
Remove the push button cover
and check / replace the push
button assembly.
Remove the shower flow
cartridge and check / replace if
necessary. Refer to maintenance
section (pages 15-16).
Remove the push button cover
and check / replace the push
button assembly. Refer to
installation section (page 12).
Open the isolation valve on the
telescopic connection.
Check any isolation valves to the
water supply are open.
Check water supply pressure.
Refer to specification section for
minimum working pressure.
Remove the shower flow
cartridge and check / replace if
necessary. Refer to maintenance
section (pages 15-16).
19

Advertisement

Table of Contents
loading