3. Electric Start and Recoil Start Operations Flip
the engine switch to"OFF"(O) position.
4. Flip the battery switch on "
OFF"(O) position.
THE BATTERY SWITCH ALWAYS SHOULD BE IN
"OFF"(O) POSITION AT THE END OF USE TO
PREVENT BATTERY DRAIN.
5. Turn the fuel valve to the "OFF"(O) position.
English
15
If a cover is used, do not install until unit has cooled.
WARNING
Fuel and its vapors are extremely flammable and
explosive which could cause burns, fire or explosion
resulting in death, serious injury and/or property
damage.
DO NOT stop engine by moving choke control to
"START" position.
Important: Always ensure that the Fuel Valve and
the Engine Switch are in the "OFF" position when
the engine is not in use.
If the engine will not be used for a period of two
weeks or longer, please see the Storage section for
proper engine and fuel storage.

Low Oil Shutdown

If the engine oil drops below a preset level, an oil
switch will stop the engine. Check oil level with
dipstick.
If oil level is between LOW and HIGH mark on
dipstick:
1.DO NOT try to restart the engine.
2.Contact an Authorized FIRMAN Service Dealer.
3.DO NOT operate engine until oil level is
corrected.
If oil level is below LOW mark on dipstick:
1.Add oil to bring level to HIGH mark.