Battery Replacement; Service And Storage - Firman P08004 Owner's Manual

Hide thumbs Also See for P08004:
Table of Contents

Advertisement

Available languages

Available languages

1.
Remove the spark plug wire from spark
plug.
2.
Remove the nut and bolt from the
negative(-) and positive(+) posts.
3.
Loosen and remove the screw A on the
battery holding bracket.
4.
Remove the battery and recycle and
dispose of properly.
5.
Install the new battery with follwoing
specification:
12V sealed lead acid 15AH
LXWXH:180X75X165mm(7.09X2.95X6.5inch) 6.
Connect the red positive(+) battery cable to the
battery first.
7.
Connect the black positive(-) battery cable
to the battery second.
8.
Cover the post with boots.
9.
Install the spark plug wire onto spark plug.
WARNING
To avoid electric shock:
ALWAYS connect the positive (+) battery cable (red
boot) first when connecting battery cables. ALWAYS
disconnect the negative (-) battery cable (black
boot) first when disconnecting battery cables.
NEVER connect the negative (-) battery cable (black
boot) to the positive (+) post on the battery.
NEVER connect the positive (+) battery cable
(red boot) to the negative (-) post on the battery.
NEVER touch both battery posts simultaneously.
NEVER place a metal tool across both battery posts.
English
21
ALWAYS use insulated or nonconducting tools
when installing the battery.
Battery Replacement On Remote
1.
Loosening and remove cover screws.
2.
Remove the cover.
3.
Remove the depleted batteries and insert
two new CR2016 lithium batteries with the
terminal facing up.
4.
Close the remote cover and tight the
screws.

SERVICE AND STORAGE

Infrequent Service
If the unit is used infrequently, difficult starting may
result. To eliminate hard starting, follow these
instructions:
1.
Run the generator at least 30 minutes
every
month.
2.
Run the generator, then close the fuel
shut-off
valve and allow the unit to run until the
engine
stops.
3.
Move the engine switch to the "OFF"
position.
Long Term Storage
It is important to prevent gum deposits from
forming in essential fuel system parts such as the
carburetor, fuel hoses or tank during storage. Also,
experience indicates that alcohol-blended fuels
(called gasohol, ethanol or methanol) can attract
moisture, which leads to separation and formation of
acids during storage. Acidic gas can damage the fuel
system of an engine while in storage.
When the generator set is not being operated, or is
being stored for more than one month, follow these
instructions to avoid engine problems: 1-ADD a
Lithium Battery
Customer Service: 1-844-FIRMAN1Page
"+"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents