Firman P01201 Owner's Manual
Hide thumbs Also See for P01201:

Advertisement

Quick Links

OWNER'S MANUAL
PORTABLE GENERATOR
IMPORTANT:
Record product information to reference when ordering parts or
obtaining warranty coverage.
DO NOT RETURN TO
STORE!
CALL US FIRST!
CUSTOMER HOTLINE
1-844-347-6261
FOR QUESTIONS OR SERVICE
INFORMATION
Read all safety precautions and instructions carefully
before operating equipment.
Ensure engine is stopped and level before performing
any maintenance or service.
MODEL NUMBER
P01201
Serial Number:
Purchase Date:
P/N:312745450 Rev:01
Rev Level:01

Advertisement

Table of Contents
loading

Summary of Contents for Firman P01201

  • Page 1 OWNER’S MANUAL PORTABLE GENERATOR MODEL NUMBER P01201 Rev Level:01 IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Ensure engine is stopped and level before performing any maintenance or service. Record product information to reference when ordering parts or obtaining warranty coverage.
  • Page 2: Table Of Contents

    Table of Contents Introduction ......1 Trouble Shooting .....23 Safety Precautions .
  • Page 3: Introduction

    Save these original instructions for future reference. This manual covers operation and maintenance of the FIRMAN generators. All information in this publication is based on the latest production information available at the time of approval for printing.
  • Page 4: Safety Precautions

    SAFETY PRECAUTIONS WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. WARNING Certain components in this product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
  • Page 5 CORRECT USAGE Example location to reduce risk of carbon monoxide poisoning • ONLY use outside and downwind, far away from windows, doors and vents. • Direct exhaust away from occupied spaces. INCORRECT USAGE Do not operate in any of the following locations: Near any door, window or vent Garage Basement...
  • Page 6 WHEN OPERATING EQUIPMENT WARNING • DO NOT operate this product inside any S t a r t e r c o r d k i c k b a c k ( r a p i d building, carport, porch, mobile equipment, retraction) will pull hand and arm marine applications, or enclosure.
  • Page 7 • When using generator for backup power, WARNING notify utility company. Unintentional sparking • Use a ground fault circuit interrupter (GFCI) could cause fire or in any damp or highly conductive area, electric shock resulting such as metal decking or steel work. in death or serious •...
  • Page 8: Unpacking The Generator

    NOTE: 1. Engine Oil(Bottle) ..... . . 1 Improper treatment of generator could damage 2. Oil Funnel ....... 1 it and shorten its life.
  • Page 9: Removal Of Shipping Supports

    REMOVAL OF SHIPPING SUPPORTS Before you can run your new generator, follow these simple instructions: CAUTION 3. You may discard these brackets, as they are no longer Failure to remove these items can result required for normal operation of your generator. in damage to your generator, possible Your generator is now ready for use.
  • Page 10: Controls And Features

    11- Control Panel 4- Choke Lever 5- Fuel Valve 6- Air Filter 7- 80cc FIRMAN OHV Engine 8- Recoil Starter *We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on this page.
  • Page 11: Control Panel

    Control Panel NOTE: Total power drawn from all receptacles must not exceed the name plate rating. Engine Switch – Flip the switch to the “ON”(l) Ground Terminal – Consult an electrician position and pull the recoil starter to start for local grounding regulations. the generator.
  • Page 12: Specifications

    LD E6RTC/NGK BPR6HS/BOSCH W26BC AN IMPORTANT MESSAGE ABOUT TEMPERATURE: Your Firman Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40°C (104°F). When your product is needed, your product may be operated at temperatures ranging from -15°C (5°F) to 50°C (122°F) for short periods. If the product is exposed to temperatures outside this range during storage, it should be brought back within this range before operation.
  • Page 13: Add Engine Oil

    4.Using oil funnel, slowly pour contents of Add Engine Oil provided oil bottle into oil fill opening to the "H" mark on dipstick. Be careful do not CAUTION overfill. Overfilling with oil could cause the DO NOT attempt to crank or start the engine engine to not start or hard starting.
  • Page 14: Add Fuel

    To alleviate high fuel expansion. altitude issues other than the natural 3.Install fuel cap and let any spilled fuel power loss, FIRMAN can provide a high evaporate before starting engine or wipe up altitude carburetor main jet. The alternative any spilled gasoline.
  • Page 15: Grounding

    Customer Support. Installation instructions are also available in the Connections for standby power to a building's Technical Bulletin area of the FIRMAN internet site. electrical system must be made by a qualified electrician. The connection must isolate the...
  • Page 16: Operation

    OPERATION • Operate this product ONLY outside far away Generator Location from windows, doors and vents to reduce the risk of carbon monoxide gas from WARNING accumulating and potentially being drawn Make sure you review each warning in order to towards occupied spaces.
  • Page 17: Starting The Generator

    7. Pull the starter cord slowly until resistance is Starting the Generator felt and then pull rapidly. 1. Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment. 2. Check oil level and fuel. 8.
  • Page 18: Connecting Electrical Loads

    Connecting Electrical Loads electrical system, consult your local utility company or a qualified electrician. Connections This unit has been pretested and adjusted to must isolate generator power from utility handle its full capacity. Before starting the power and must comply with all applicable laws generator, disconnect all load.
  • Page 19: Low Oil Shutdown

    7. Repeat steps 5-6 for each additional item. 1.DO NOT try to restart the engine. 2.Contact an Authorized FIRMAN Service Dealer. 3.DO NOT operate engine until oil level is corrected. If oil level is below LOW mark on dipstick: 1.Add oil to bring level to HIGH mark.
  • Page 20: Maintenance And Storage

    MAINTENANCE AND STORAGE MAINTENANCE SCHEDULE Every Daily(Before Initial Every 100 hours ITEM NOTES operation) 25 hours 50 hours (or annual) Check condition. Adjust gap √ Spark Plug and clean. Replace if necessary. √ Check oil level. Engine Oil √ √ Replace.
  • Page 21: Engine Maintenance

    • Use fresh and high quality lubricating oil to the ENGINE MAINTENANCE specified quantity. If contaminated or deteriorated oil is used or To prevent accidental starting, remove and the quantity of the engine oil is not sufficient, ground spark plug wire before performing any the engine damage will result and its life will be service.
  • Page 22: Spark Plug Maintenance

    Spark Plug Maintenance CLEANING FUEL STRAINER Changing the spark plug will help your engine Clean the screen with gasoline every 50 hours. to start easier and run better. (a) Remove the spark plug cap. (b) Remove spark plug using provided wrench. SCREEN BODY A- Spark plug...
  • Page 23: Generator Maintenance

    • DO NOT touch hot parts and AVOID hot exhaust CAUTION gases. • Failure to clean the spark arrester will result in Allow equipment to cool before touching. degraded engine performance. • Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.
  • Page 24: Service And Storage

    WARNING SERVICE AND STORAGE Generator exhaust contains odourless and Infrequent Service colourless carbon monoxide gas. If the unit is used infrequently, difficult starting To avoid accidental or unintended ignition of may result. To eliminate hard starting, follow your generator during periods of storage, the these instructions: following precautions should be followed: 1.
  • Page 25: Trouble Shooting

    TROUBLE SHOOTING Problem Cause Correction 1. Circuit breaker is open. 1. Reset circuit breaker. 2. Fault in generator. 2. Contact authorized service facility. Engine is running, but no 3. Poor connection or defective cord 3. Check and repair. AC output is available. set.
  • Page 26: Parts Diagram And Parts List

    PARTS DIAGRAM AND PARTS LIST P01201 Parts Diagram Page 24 English Customer Service: 1-844-FIRMAN1...
  • Page 27: Parts List

    152F 80cc Engine Parts Diagram Page 25 English Customer Service: 1-844-FIRMAN1...
  • Page 28: Engine Parts Diagram

    P01201 Parts List Description Qty. NO. Part Number Description NO. Part Number Qty. Engine Switch Chain 312713500 312713550 Screw M4x20 Fuel Cap 312713501 312713551 Screw M4x12 312713502 Front Cover 312713552 Outlet Cover 5-20R Flat Washer Ø8 312713503 312713553 Nut M6...
  • Page 29: Parts List

    152F 80cc Engine Parts List Qty. Qty. NO. Part Number Description NO. Part Number Description Starter Oil Channel Cover 312723500 312723552 312723501 Screw M6×10 (black) 312723553 Valve Spring Flywheel Nut Valve Retainer 312723502 312723554 312723503 Screw M6×12 312723555 Rocker Arm Seat Fan Cas Circlip 312723504...
  • Page 30: Service Information

    PRODUCT SERVICE FIRMAN GENERATOR will register the warranty upon DEPARTMENT AT receipt of your Warranty Registration Card and a copy of your sales receipt from one of FIRMAN's 1-844-347-6261 retail locations as proof of purchase. Please submit or at www.firmangenerators.com your warranty registration and your proof of purchase within ten (10) days of the date of purchase.
  • Page 31 Peoria, AZ 85381 Normal maintenance is not covered by this www.firmangenerators.com warranty. We are FIRMAN POWER - And we are here for you. Other Exclusions Customer Service Desk - 1-844-347-6261(844-FIRMAN1) This warranty excludes: 6am PST(9am EST) until 8pm EST(5pm PST) –...
  • Page 32 If any such part fails during the period of warranty coverage, the part will be repaired or replaced by FIRMAN at no charge to the owner. Any such part repaired or replaced under the warranty will be warranted for the remaining warranty period.
  • Page 33 This Emission Control Systems Warranty shall not cover any of the following: (a) Consequential damages such as loss of time, inconvenience, loss of use of the engine or equipment, etc. (b) Diagnosis and inspection fees that do not result in eligible warranty service being performed. FIRMAN POWER EQUIPMENT Email: firmangenerators@sumec-na.com www.firmangenerators.com...
  • Page 34 Firman Power Equipment Inc. 14131 N Rio Vista Blvd, Suite 9 Peoria, AZ 85381 www.firmangenerators.com P/N:312745450 Rev 0 1...

Table of Contents