WIRING DIAGRAMS
Below, you will find the following wiring diagrams of the Detecta-6 system in ADS and
4+N/MDS installations:
ADS installations

- Wiring diagram of the Detecta-6 1-line ADS Video-entryphone Kit.

- Wiring diagram of the Detecta-6 1-line ADS Building Video-entryphone Kit.

- Wiring diagram with Detecta-6 ADS Telephone

- Wiring diagram with Detecta-6 ADS Telephone and Monitor

MDS/4+N Installations
- Wiring diagram with Detecta-6 4+N Monitor
Notes:
- Maximum number of Detecta-6 terminals in the same home: 3.
- Maximum distance from the central unit to the last Detecta-6 terminal: 100m.
It is possible to expand the installation with «non-Detecta-6» monitors/telephones,
provided the power supply is adequate.
The limitation on the number of «non-Detecta»-6 ADS or 4+N terminals is determined
by the capacity of the power supply.
- In installations with more than one monitor per home, cut the 75-ohm resistance
of the connector («R»), of all the monitors except the last one.
Pag 22
max. 100m
F E R M A X
1
2
3
4
5
6
max. 3
R
1
2
3
4
5
6
F E R M A X
3
1
2
4
5
6
F E R M A X
3
1
2
4
5
6