Roberts Gorden Vantage HEM-80 Installation, Operation & Service Manual page 28

Gas-fired, low intensity unitary heater
Table of Contents

Advertisement

HEM-S
I
, O
ERIES
NSTALLATION
PERATION AND
Step 6.6.1 Reflector, U-Clip and Reflector Support Installation
The pictorial drawings of the heater construction in
Section 6 are schematic only and provide a general
guideline of where hangers, reflector supports and
U-clips are to be installed.
To ensure proper expansion and contraction
movement of the reflectors, a combination of U-clips
and reflector supports are used. The positioning of
1. Slide first reflector after burner a minimum 2" (4 cm) through first hanger and
ensure reflector end cap is securely fastened via U-clips, pop rivets, or sheet
metal screws. Position reflector support with tight screws in middle of first
reflector.
Description
Reflector Support Package
Wire Form
Reflector Support Strap
Screw #8 x 3/4
U-Clip Package
Reflector End Cap
24 of 80
S
M
ERVICE
ANUAL
Part Number
0305001X
NOTE: High efficiency
91908004
reflectors should NOT
0305000X
be used in applications
94320812
exposed to wind.
91107720
027508XX
reflector supports and U-clips depends on the
individual installation. Use either pop rivets or sheet
metal screws instead of u-clips when installing end
caps and joint pieces in areas where impact and high
wind may be a factor. The following rules must be
observed.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vantage hem-115Vantage hem-150Vantage hem-200

Table of Contents