ACU-RITE 06021RM Instruction Manual

ACU-RITE 06021RM Instruction Manual

Display for 3-in-1 weather sensor

Advertisement

Quick Links

Package Contents
1. Display unit
2. Power adapter
3. Instruction Manual
This product requires an AcuRite 3-in-1 Weather Sensor (sold separately) to be
operational.
IMPORTANT
PRODUCT REGISTRATION
Register online
to receive 1 year
warranty protection
www.AcuRite.com
Questions?
(877) 221-1252 or visit www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Display for 3-in-1 Weather Sensor
h
h
i
i
g h
h
low
average
12-24 hour forecast
h igh
low
TIM E
Contact Customer Support at
h
h
i
i
g h
h
heat ind ex
w
wind chill
hil
low
d
ew point
WIND
MPH
peak
current
KPH
auto
manual
barometer
Learning...
high indoor humidity!
h igh
low i n door h umidity !
low
AUTO DST O N O FF
OCT
AU TO DIM
ZON E
PRODUCT MUST BE REGISTERED
TO RECEIVE WARRANTY SERVICE
Register a Product
Instruction Manual
model 06021RM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 06021RM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ACU-RITE 06021RM

  • Page 1 Instruction Manual Display for 3-in-1 Weather Sensor model 06021RM heat ind ex wind chill ew point WIND average peak current auto manual 12-24 hour forecast barometer Learning... high indoor humidity! h igh h igh low i n door h umidity !
  • Page 2: Features And Benefits

    Features & Benefits heat index wind chill ew point WIND average peak current auto manual 12-24 hour forecast barometer Learning... high indoor humidity! high high low indoor h r umidity! AUTO DST ONOFF TIME AUTO DIM ZONE DISPLAY UNIT 1. Current Outdoor Temperature 10.
  • Page 3 Features & Benefits BACK OF DISPLAY UNIT 5. Battery Compartment 6. Plug-in for Power Adapter Button for setup preferences. 7. A-B-C Switch ID code that must match sensor’s A-B-C Button switch to ensure units synchronize. for setup preferences. 8. Reset Button Button Full reset to factory defaults.
  • Page 4: Display Unit Setup

    Display Unit Setup Set the A-B-C Switch 2. Insert 3 x AAA alkaline batteries into the battery Locate the A-B-C switch inside compartment, as shown. the battery compartment. Set Follow the polarity (+/–) the A-B-C switch to A, B or C. diagram in the battery You must select the same letter compartment.
  • Page 5: Set The Time, Date & Units

    Set the Time, Date & Units Press the “ ” button, located on the front of the display unit, to enter SET MODE. Once in set mode, the preference you are currently setting will blink on the display. To adjust the currently selected (flashing) item, press and release the “ “ or “...
  • Page 6: Weather Forecast

    OPERATION Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display unit and the sensor are critical to the accuracy and performance of this product. Display Unit Placement heat index wind chill ew point Place the display unit in a dry area free of dirt and dust.
  • Page 7: Barometric Pressure

    Barometric Pressure Subtle variations in barometric pressure greatly impact the weather. This weather center displays the current pressure with an arrow icon to indicate the direction the pressure is trending (FALLING, STEADY, or RISING). Moon Phase Track the phases of the moon, conveyed through simple lunar phase icons: WAXING FULL WANING...
  • Page 8: Care And Maintenance

    Care & Maintenance Display Unit Care Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air. Calibration The indoor / outdoor temperature and humidity readings, and barometric pressure can be calibrated on the display unit to improve accuracy.
  • Page 9: Replace Intelli-Time

    Replace Intelli-Time Clock Battery ® Intelli-Time technology is powered by a pre-installed coin-cell battery that stores the time and date settings. The battery has a shelf life of several years. To replace the Intelli-Time battery: 1. Locate the coin cell battery compartment door on the back of the display unit.
  • Page 10: Specifications

    Specifications Outdoor: -40ºF to 158ºF; -40ºC to 70ºC TEMPERATURE RANGE Indoor: 32ºF to 122ºF; 0ºC to 50ºC Outdoor: 1% to 99% HUMIDITY RANGE Indoor: 1% to 99% 0 to 99 mph; 0 to 159 kph WIND SPEED 330 ft / 100 m depending on home construction materials WIRELESS RANGE 433 mhz OPERATING FREQUENCY...
  • Page 11: Customer Support

    Customer Support AcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us in any of the following ways: (877) 221-1252 info@chaney-inst.com AcuRite 24/7 support at www. .com Installation Videos Register your Product...
  • Page 12 ©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copy- rights are the property of their respective owners. AcuRite uses patented technology. Printed in China 06021RM INST 091014 Visit www.AcuRite.com/patents for details.