Environmental Specifications

Note:
Adaptec RAID controllers require adequate airflow to operate reliably. The recommended
airflow is 200 LFM. Forced airflow is recommended.
Ambient temperature with forced airflow
Ambient temperature without forced airflow
Ambient temperature with Battery Backup Unit
(BBU)
Relative humidity
Altitude
Note:
Ambient temperature measured 1" from RAID processor.

DC Power Requirements

Bus Type
PCIe
PCIe

Current Requirements

Adaptec Model
Adaptec RAID 5085
Adaptec RAID 5805
Adaptec RAID 5405
Adaptec RAID 5445
Adaptec RAID 5805Z
Adaptec RAID 5405Z
Adaptec RAID 5445Z
Adaptec RAID 51245
Adaptec RAID 51645
Adaptec RAID 52445
Adaptec RAID 2045
Adaptec RAID 2405
Appendix H: Technical Specifications
0 °C to 55 ° C
0 °C to 40 ° C
0 °C to 40 ° C
10% to 90%, noncondensing
Up to 3,000 meters
Description
Ripple and noise
DC Voltage
Typical Current
0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
0.45A @ 3.3VDC; 0.94A @ 12.0VDC
0.45A @ 3.3VDC; 1.0A @ 12.0VDC
0.39 A @ 3.3 VDC; 1.21 A @ 12.0 VDC
0.38 A @ 3.3 VDC; 1.18 A @ 12.0 VDC
0.40 A @ 3.3 VDC; 1.24 A @ 12.0 VDC
0.47A @ 3.3VDC; 1.68A @ 12.0VDC
0.47A @ 3.3VDC; 1.72A @ 12.0VDC
0.47A @ 3.3VDC; 1.78A @ 12.0VDC
0.43A @ 3.3VDC; 0.83A @ 12.0VDC
0.43A @ 3.3VDC; 0.83A @ 12.0VDC
Requirements
50 mV peak-to-peak (max)
3.3 V ± 9%, 12 V ± 8%