Sharp DV-NC100S Service Manual page 109

Vcr/dvd combination
Hide thumbs Also See for DV-NC100S:
Table of Contents

Advertisement

5. To shift the CTL waveform, press CH UP or CH
DOWN button on the remote control unit. Then make
sure that the maximum output position of PB FM
envelope signal become within ±2ms from preset
position.
Good
FM envelope signal
FM envelope output signal
is adjusted at maximum.
No Good
FM envelope output signal is low.
6. Set the Tracking Control Circuit to the preset position
by pressing CH UP button on the remote control unit.
and then "PLAY" button.
1-C. Checking/Adjustment of Enve-
lope Waveform
Purpose:
To achieve a satisfactory picture, adjust the PB FM
envelope becomes as flat as possible.
Symptom of Misalignment:
If the envelope output is poor, noise will appear in the
picture. The tracking will then lose precision and the
playback picture will be distorted by any slight variation
of the Tracking Control Circuit.
1. Connect the oscilloscope to TP301 (C-PB) on the
Main CBA. Use TP504 (RF-SW) as a trigger.
2. Playback the Gray Scale on the Test Tape (FL6NS8).
Set the Tracking Control Circuit to the preset position
by pressing CH UP button and then "PLAY" button on
the unit. Adjust the height of Guide Rollers [2] and [3]
(Fig. M3, Page 2-3-3) watching the oscilloscope dis-
play so that the envelope becomes as flat as possible.
To do this adjustment, turn the top of the Guide Roller
with the Guide Roller Adj. Screwdriver.
3. If the envelope is as shown in Fig. M7, adjust the
height of Guide Roller [2] (Refer to Fig. M3) so that the
waveform looks like the one shown in Fig. M9.
2ms
Center Position
CTL signal
Fig. M7
4. If the envelope is as shown in Fig. M8, adjust the
height of Guide Roller [3] (Refer to Fig. M3) so that the
waveform looks like the one shown in Fig. M9.
5. When Guide Rollers [2] and [3] (Refer to Fig. M3) are
aligned properly, there is no envelope drop either at
the beginning or end of track as shown in Fig. M9.
Dropping envelope level at the beginning of track.
Dropping envelope level at the end of track.
Envelope is adjusted properly. (No envelope drop)
Note: Upon completion of the adjustment of Guide
Rollers [2] and [3] (Refer to Fig. M3), check the X Value
by pushing the CH UP or DOWN buttons alternately, to
check the symmetry of the envelope. Check the number
of pushes to ensure preset position. The number of
pushes CH UP button to achieve 1/2 level of envelope
should match the number of pushes CH DOWN button
from center. If required, redo the "X Value Alignment."
2-3-4
Fig. M8
Fig. M9
Fig. M10
H9740MA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dv-nc100ssDv-nc100sqDv-nc100syDv-nc100sr